Báo cáo khoa học: " Equipment review: The molecular adsorbents recirculating system (MARS®)" ppsx

Báo cáo khoa học: " Equipment review: The molecular adsorbents recirculating system (MARS®)" ppsx

Báo cáo khoa học: " Equipment review: The molecular adsorbents recirculating system (MARS®)" ppsx

... replacement therapy; CVVHD = continuous veno-venous haemodialysis; MARS = molecular adsorbents recirculating system. Critical Care August 2004 Vol 8 No 4 Boyle et al. Review Equipment review: The molecular ... but other less common causes such 281 Available online http://ccforum.com/content/8/4/280 What is the science underlying the technology? Molecular adsorbents re...
Ngày tải lên : 12/08/2014, 20:20
  • 7
  • 482
  • 0
Báo cáo khoa học: "Equipment review: The success of early goal-directed therapy for septic shock prompts evaluation of current approaches for monitoring the adequacy of resuscitation" potx

Báo cáo khoa học: "Equipment review: The success of early goal-directed therapy for septic shock prompts evaluation of current approaches for monitoring the adequacy of resuscitation" potx

... to other organs [72]. Second, the gut has been hypothesized to be the ‘motor’ of the multiple organ system dysfunction syndrome [73], and in experimental models intestinal mucosal acidosis, whether ... P CO 2 in other nongastric sites, such as the space under the tongue, may require even less invasion of the patient and yet be as informative as measuring P CO 2 in the wall of...
Ngày tải lên : 12/08/2014, 22:22
  • 11
  • 381
  • 0
Báo cáo y học: "Effect of the molecular adsorbent recirculating system and Prometheus devices on systemic haemodynamics and vasoactive agents in patients with acute-on-chronic alcoholic liver failure" potx

Báo cáo y học: "Effect of the molecular adsorbent recirculating system and Prometheus devices on systemic haemodynamics and vasoactive agents in patients with acute-on-chronic alcoholic liver failure" potx

... (a) the molecular adsorbent recirculating system and (b) the Prometheus systemSchematic representation of both liver assist devices: (a) the molecular adsorbent recirculating system and (b) the ... medical therapy alone (SMT), (b), (e) the molecular adsorbent recirculating system (MARS) and (c), (f) the Prometheus (PROM) systemIndividual values for the mean ar...
Ngày tải lên : 13/08/2014, 01:20
  • 13
  • 432
  • 0
Báo cáo khoa học: "Equipment review: An appraisal of the LiDCO™plus method of measuring cardiac output." docx

Báo cáo khoa học: "Equipment review: An appraisal of the LiDCO™plus method of measuring cardiac output." docx

... in the doses used and the maximum dose is rarely a limiting factor. The equipment is generally reliable, although there have been manufacturing problems with the lithium sensors in the past. There ... patients in the intensive care unit, operating theatre and other critical care areas. Because of the minimally invasive nature of the technology, the device may be used more...
Ngày tải lên : 12/08/2014, 20:20
  • 6
  • 365
  • 0
Tài liệu Báo cáo khoa học: Analysis of the molecular dynamics of medaka nuage proteins by fluorescence correlation spectroscopy and fluorescence recovery after photobleaching doc

Tài liệu Báo cáo khoa học: Analysis of the molecular dynamics of medaka nuage proteins by fluorescence correlation spectroscopy and fluorescence recovery after photobleaching doc

... visualize the localization and to mea- sure the mobility of the components in the PGCs. The medaka embryo was peeled off the chorion, and the segment containing the part of PGCs was excised for observation ... movement in the granules and diffused in the cytosol of HeLa cells, just as in the medaka embryo. The other two gene products, Nanos and Tudor of the medaka, w...
Ngày tải lên : 18/02/2014, 16:20
  • 9
  • 655
  • 0
Báo cáo khoa học: "Clinical review: The implications of experimental and clinical studies of recruitment maneuvers in acute lung injury" pptx

Báo cáo khoa học: "Clinical review: The implications of experimental and clinical studies of recruitment maneuvers in acute lung injury" pptx

... integrins. These receptors transmit forces from the surrounding matrix to the cytoskele- ton via the focal adhesion complex [11]. When the basement membrane is strained, adherent epithelial cells ... change shape and the ratio of their surface (plasma membrane) to their volume must increase. If the plasma membrane is dis- rupted the intracellular lipid stores are utilized to rep...
Ngày tải lên : 12/08/2014, 19:22
  • 7
  • 287
  • 0
Báo cáo khoa học: "Clinical review: The Israeli experience: conventional terrorism and critical care" docx

Báo cáo khoa học: "Clinical review: The Israeli experience: conventional terrorism and critical care" docx

... affects the solid organs. The probability of being injured as a result of each of these mechanisms is determined by the distance of the casualty from the epicenter of the explosion and whether it ... space. The presence of penetrating shrapnel injury signifies the proximity of the casualty to the epicenter of the explosion. The finding of shrapnel injury to one body re...
Ngày tải lên : 12/08/2014, 22:22
  • 10
  • 283
  • 0
Báo cáo khoa học: "Clinical review: The meaning of acid–base abnormalities in the intensive care unit – epidemiolog" ppt

Báo cáo khoa học: "Clinical review: The meaning of acid–base abnormalities in the intensive care unit – epidemiolog" ppt

... phosphates. The total charge of these must equal the SIDa. The product of all of the measurable anions contributing to the balancing negative charge is referred to as the effective SID (SIDe). Theoretically, ... value rather than to take into account the physicochemical principles of either the decreased ratio of sodium to chloride or the decreased difference between them. W...
Ngày tải lên : 12/08/2014, 22:22
  • 9
  • 371
  • 0
Báo cáo khoa học: " Equipment review: Cooling catheters to induce therapeutic hypothermia" docx

Báo cáo khoa học: " Equipment review: Cooling catheters to induce therapeutic hypothermia" docx

... temperature of 4-5°C) in the external device (the CoolGard 3000 ® ) and then pumped through the balloons coaxially mounted on the catheter, enabling direct cooling of the blood. The catheter contains ... loop’ temperature control system; the temperature is set at the desired level (the range of the device is 28-38°C, which may vary according to the installed software), af...
Ngày tải lên : 13/08/2014, 03:20
  • 4
  • 247
  • 0