Endovascular Aneurysm Repair - part 10 ppsx

Endovascular Aneurysm Repair - part 10 ppsx

Endovascular Aneurysm Repair - part 10 ppsx

... DC (1996) Endovascular stent-graft repair of thoracic aortic aneurysms. J Thorac Car- diovasc Surg 111 :104 5 106 2 4. Hata M, Tanaka Y, Iguti A, Saito H, Ishibashi T, Tabayashi K (1999) Endovascular repair ... (TRA) U ultrasound scanning, intravascular (IVUS) 80, 81, 100 , 102 , 105 , 109 , 113, 115, 119, 124 ± aneurysm repair 103 ± cross section 81, 103 ± dissection 119...

Ngày tải lên: 12/08/2014, 00:22

10 142 0
Endovascular Aneurysm Repair - part 5 pdf

Endovascular Aneurysm Repair - part 5 pdf

... abdominal aortic aneurysms. Circulation 90 [part 2](5):II-224±II-227 46. Anidjar S, Salzmann J-L, Gentric D, Lagneau P, Camilleri J-P, Michel J-B (1990) Elastase-induced experimental aneurysms in ... enabling retrograde aneurysm perfu- sion, and the potential of aneurysm shrinkage following endovascular ex- clusion in case an autologous patch is used. Thrombosis of untreated aneu- rys...

Ngày tải lên: 12/08/2014, 00:22

14 140 0
Endovascular Aneurysm Repair - part 7 docx

Endovascular Aneurysm Repair - part 7 docx

... EPs and the non-oversized EPs at im- plantation (left) and follow- up (right). a Talent; b Talen- tLoPro; c Stenway; d Walls- tent; e Non-oversized. Scale is 4.0 mm/div ] Talent TM -EPs made of ... Stenway- and in particular of the Wallstent-EPs were smaller. Yet the smallest perfused lumina were present in the non-oversized EPs. The comparison between the TalentLoPro- and the non-oversized ....

Ngày tải lên: 12/08/2014, 00:22

14 123 0
Endovascular Aneurysm Repair - part 8 pptx

Endovascular Aneurysm Repair - part 8 pptx

... ultrasound (IVUS) creates high-quality cross-sectional views and might therefore be equally impor- tant for an endovascular repair. IVUS interrogation of aortic aneurysms al- lows for precise measurements ... and fluoroscopy for en- dovascular aneurysm repair. He is particularly familiar with the angio- graphic appearance of the aorta and the plain view of the device as it ap- pears on...

Ngày tải lên: 12/08/2014, 00:22

14 164 0
Endovascular Aneurysm Repair - part 9 potx

Endovascular Aneurysm Repair - part 9 potx

... transection: The endovascular ex- perience. Ann Thorac Surg 75 :106 ±112 8. Doss M, Balzer J, Martens S, Wood JP, Wimmer-Greinecker G, Fieguth H-G, Moritz A (2003) Surgical versus endovascular treatment ... ultra- sound aids in the performance of endovascular repair of abdominal aortic aneu- rysm. J Vasc Surg 37:615±618 9. Slovut DP, Ofstein LC, Bacharach JM (2003) Endoluminal AAA re...

Ngày tải lên: 12/08/2014, 00:22

14 115 0
Inspection Evaluation And Repair Of Steel structures Part 10 ppsx

Inspection Evaluation And Repair Of Steel structures Part 10 ppsx

... src="data:image/png;base64,iVBORw0KGgoAAAANSUhEUgAAAvkAAATaCAIAAABHNu6NAAAACXBIWXMAABYlAAAWJQFJUiTwAAAgAElEQVR42u3dfaxkZWH48ec012DcKiJeJHW1u8US3PCyTdEaVjszBWkatFBeQsXGxKZYW42mtk0a+8ecwaSNSWsjJtqmSf/AIhQDRMoWtl32ngEuSiqlhS19C+xCl/ByacSVNWzYZn5/PN3nd5y5e3fuvXPnzjzz+fxBLrP3ZebcuXO+85znPKfo9XqBjXHaaae9/PLLY/txF 1100 eLios0OAHVzNsHGefnllw8cODC2H7dlyxbbHAD6FMZ1NsixY8de97rX2bwAsLl+zCbYIIcOHXrzm99sOw...

Ngày tải lên: 05/08/2014, 11:20

10 349 0
Peterson’s master toefl reading skills part 10 ppsx

Peterson’s master toefl reading skills part 10 ppsx

... 3,3 1-9 1 7/29/06, 12:0059 60 PART III: TOEFL Reading Review www.petersons.com 8. The correct answer is true. 9. The correct answer is true. 10. The correct answer is false. Not a superstition part ... career. Ex-wives are faring better in the pension-sharing dilemma than they are in obtaining health coverage. The courts have set a precedent in awarding pension funds to divorced women,...

Ngày tải lên: 01/07/2014, 10:44

7 921 3
Algorithms and Data Structures in C part 10 ppsx

Algorithms and Data Structures in C part 10 ppsx

... look and feel of a hypercube yet without the high degree. The cube-connected cycles topology has nlog n nodes. Figure 2.18 Cube-Connected Cycles 2.6 The Hypercube Topology This section presents ... has three neighbors: Figure 2.17 Hypercube Topology 2.5.3.4CubeConnectedCycles A cube-connected cycles topology is shown in Figure 2.18. This topology is easily formed from the hy...

Ngày tải lên: 02/07/2014, 08:21

6 380 0
Recent Developments of Electrical Drives - Part 10 ppsx

Recent Developments of Electrical Drives - Part 10 ppsx

... node i. j+n+1 i+k+2 j+n j i i+k j+n-i i+k-1 j+n-2 j-1 j-2 i-1 i-2 i+2 i+1 Figure 4. Part of the one level(z =const.) of the mesh with the overlappingregion(parts of electrodes dashed, dimensions ... dimensions enlarge)—symmetrical air gap. I-7. Analysis of Electrostatic Microactuators 77 j+n+1 i+k+2 j+n j i i+k j+n-i i+k-1 j+n-2 j-1 j-2 i-1 i-2 i+2 i+1 Figure 5. Part of the one level(z =c...

Ngày tải lên: 02/07/2014, 09:20

10 351 0
w