Air Sampling and Industrial Hygiene Engineering - Chapter 11 pps
... headaches, and vomiting. High exposures may cause convulsions and coma and irregular heartbeat. Repeated exposure can damage the blood-forming organs, caus- ing aplastic anemia. Long-term exposure ... exhaust ventilation. 11. 6.7 Noise In welding and cutting and the associated operation, noise levels may exceed the per- missible limits. Personal hearing protective devices may be ne...
Ngày tải lên: 11/08/2014, 06:22
... Cataloging-in-Publication Data Boss, Martha J. Air sampling and industrial hygiene engineering / Martha J. Boss, Dennis W. Day. p. cm. Includes bibliographical references and index. ISBN 1-5 667 0-4 1 7-0 ... Press LLC 11 Monitoring for Toxicological Risk 11. 1 Types of Sampling 11. 1.1 Long-Term Samples 11. 1.2 Short-Term Samples 11. 1.3 Area Samples 11. 1.4 Wipe...
Ngày tải lên: 11/08/2014, 06:22
... air sampling and air sample analysis, bulk sampling and bulk sample analysis, and negative air pressure maintenance. Personnel records include résumés, certifications, medical surveillance, and ... sample. The sampling may be for a full-shift sample or for a short period ceiling determination. 4.5.2 Full-Period, Consecutive Sampling Full-period, consecutive sampling is...
Ngày tải lên: 11/08/2014, 06:22
Air Sampling and Industrial Hygiene Engineering - Chapter 7 pps
... ASHRAE handbook, ASHRAE Standard 62, and the requirements of NFPA Standards Nos. 90A, 90B, and 91. Motorized low-leakage dampers, with blade and jamb seals, should be provided at all outside air intakes ... Barometric pressure and air temperature should be noted when using air veloc- ity meters. © 2001 CRC Press LLC designed in accordance with ASME B19. 1-1 985 and B19.1a-1...
Ngày tải lên: 11/08/2014, 06:22
Air Sampling and Industrial Hygiene Engineering - Chapter 9 pps
... minimum site-specific, task-specific, and hazard-specific proce- dures, precautions, and equipment determined necessary and described in the HSDA are clearly biddable and enforceable contractual requirements ... containers, and training for employees. There must be open communica- tion between all parties involved with hazardous material, including employer-employee, employee-employ...
Ngày tải lên: 11/08/2014, 06:22
Air Sampling and Industrial Hygiene Engineering - Chapter 2 pdf
... or on-site immunoassay testing must be accomplished. Therefore, until results are obtained and inter- preted, on-site personnel would be required to wear HEPA-OV cartridge full- face air- purifying ... l/min. High-flow pumps are used for asbestos, PAHs in indoor air, PM10 and PM2.5 in indoor air, bioaerosol sampling, stack sampling, fenceline monitoring, and background monitoring....
Ngày tải lên: 11/08/2014, 06:22
Air Sampling and Industrial Hygiene Engineering - Chapter 3 potx
... calibrate an air sampling pump. (SKC—AirCheck ® 2000 air sampling pump, CalCheck ® Communicator with DC-Lite calibrator). (Bios International Corp.) Figure 3.9 The electronic standardization and communication ... Secondary standard rotameters are used in the field to calibrate air- sampling pumps. Rotameters are calibrated to a primary standard. Flow rates must be corrected for s...
Ngày tải lên: 11/08/2014, 06:22
Air Sampling and Industrial Hygiene Engineering - Chapter 5 docx
... worst-case scenario for soils and are evalu- ated using log-normal distribution, Kriging, or Monte Carlo analysis. Ground- and surface-water samples are collected (20 samples per location) and ... and engineering controls may require air monitoring of personnel, area of influence, and the site perimeter. In order to understand the context under which air monitoring protocols...
Ngày tải lên: 11/08/2014, 06:22
Air Sampling and Industrial Hygiene Engineering - Chapter 6 ppt
... Acombination of contact and air- sampling information is required to assess most buildings (Figure 6.1), and these acceptable numbers vary given different biological con- taminant mixes and building usage. ... Epidermophyton, Microsporum, and Trichophyton Skin, hair, and nail infections by these dermatophytid molds are among the most prevalent of human infections. Agents are pres...
Ngày tải lên: 11/08/2014, 06:22
Air Sampling and Industrial Hygiene Engineering - Chapter 8 pptx
... Reconnaissance Research previous soil surveys, ground-penetrating radar and manometer data, and air sampling and monitoring data. Monitor atmospheric conditions and airborne pollu- tants. Such data are not a definitive ... fluid intake, and monitoring employees for symptoms, especially high-risk workers. 8.3.4.2 Air Sampling and Monitoring Example General hazards frequentl...
Ngày tải lên: 11/08/2014, 06:22