AIR POLLUTION CONTROL TECHNOLOGY HANDBOOK - CHAPTER 17 ppsx
... reactions 17. 4 and 17. 5 are (17. 6) (17. 7) Equilibrium constants at different temperatures are listed in Table 17. 1. Equi- librium concentrations calculated from Equations 17. 6 and 17. 7 are presented ... achieve early election compliance on a 372-MWe coal-fired tangential boiler, presented at EPRI-DOE-EPA Combined Utility Air Pollutant Control Symp., Wash- ington, D.C., August...
Ngày tải lên: 11/08/2014, 06:22
... 1970 amendments established a program of technology- based NSPS so that any new source of air pollution would be required to apply effective air pollution controls. New Source Performance Standards ... were not required to retrofit pollution controls. Existing sources that are modified are considered new sources, so old plants have to upgrade their air- pollution control equipme...
Ngày tải lên: 11/08/2014, 06:22
... Technologies Handbook Chang Ho Oh The MEMS Handbook Mohamed Gad-el-Hak Air Pollution Control Technology Handbook Karl B. Schnelle, Jr. and Charles A. Brown Forthcoming Titles Biomedical Technology ... in air pollution effects and control. The following brief summary leads up to the 1970 Amendments to the Clean Air Act, beginning with: The Air Pollution Control A...
Ngày tải lên: 11/08/2014, 06:22
AIR POLLUTION CONTROL TECHNOLOGY HANDBOOK - CHAPTER 3 ppt
... of air pollution. Often the selection of control technology does not depend on whether a PSD review is triggered because the same control technology will be required in any case. BACT is a technology- based ... sources of hazardous air pollutants may be regulated by the Maximum Achievable Control Technology (MACT) standards for hazardous air pollutants as discussed in the...
Ngày tải lên: 11/08/2014, 06:22
AIR POLLUTION CONTROL TECHNOLOGY HANDBOOK - CHAPTER 4 docx
... Control- technology evaluation • New-source review A current frequent use for atmospheric-diffusion models is in air- quality impact analysis. The models serve as the heart of the plan for new-source ... dispersion. AERMOD, along with AERMET, a meteorological data pre- processor, and AERMAP, a terrain data preprocessor, are state-of-the-art air quality models destined to become EPA’s re...
Ngày tải lên: 11/08/2014, 06:22
AIR POLLUTION CONTROL TECHNOLOGY HANDBOOK - CHAPTER 5 potx
... test 28 Certification and auditing of wood heaters 28A Measurement of air- to-fuel ratio and minimum achievable burn rates for wood-fired appliances TABLE 5.1 (continued) Code of Federal Regulations ... from material sources and smoke emissions from flares 23 Determination of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans from stationary sources 24 Determination of vol...
Ngày tải lên: 11/08/2014, 06:22
AIR POLLUTION CONTROL TECHNOLOGY HANDBOOK - CHAPTER 6 pps
... general continuous air- quality mon- itor. The device contains: 1. Primary air- moving device, usually a vacuum pump, to pull the air sample through the instrument 2. Flow -control and -monitoring device, ... for which concentrations are desired, i.e., 15-min, 1-h, 3-h, 8-h, 12-h, or 24-h time intervals. It should be consistent with the averaging times specified by air quality standards...
Ngày tải lên: 11/08/2014, 06:22
AIR POLLUTION CONTROL TECHNOLOGY HANDBOOK - CHAPTER 7 pps
... THER C OST -E STIMATING R ESOURCES The OAQPS Control Cost Manual does not discuss all air- pollution control devices, nor does it cover large, complex air- pollution control systems ... Exam- ples include the Marshall & Swift Equipment Cost Index and the Chemical Engi- neering Plant Cost Index. Specific to the air- pollution control industry is the Vatavuk...
Ngày tải lên: 11/08/2014, 06:22
AIR POLLUTION CONTROL TECHNOLOGY HANDBOOK - CHAPTER docx
... engineer from all other engineers. As the field of air- pollution control engineering has evolved over the past several decades, it is obvious that the air- pollution control engineer must adopt the ideas and ... – z 1 = 0.0 and α = 1.0 or Air density at 500 F: Air specific heat: C - Water specific heat C - Air enthalpy at 1: H Air enthalpy at 2: H air...
Ngày tải lên: 11/08/2014, 06:22
AIR POLLUTION CONTROL TECHNOLOGY HANDBOOK - CHAPTER 9 pot
... Here all property was classified in 3-, 5-, 1 0-, 1 5-, or 20-year service life groups with no salvage value. The majority was in the 5-year group. A ½ full-year depreciation in the year placed in ... design that will provide the desired pollution control and meet the profitability objective set as the rate of return. As pointed out above, in some cases a pollution control...
Ngày tải lên: 11/08/2014, 06:22