GENERAL ELECTRIC GENERATING PLANTS Part 11 potx
... Hot-Water Heating System NFGS-16202 Diesel -Electric Generating Plants (Design 1) 501 KW to 2500 KW Continuous-Duty units NFGS-16203 Diesel -Electric Generating Plants (Design 2) 2,501 KW and Larger ... Continuous-Duty units NFGS-16204 Diesel -Electric Generating Plants (Design 3) 301 KW to 1,000 KW Standby Emergency Duty Units NFGS-16205 Diesel -Electric Generating...
Ngày tải lên: 08/08/2014, 12:21
... construction and of nonstandard plants. iii MIL-HDBK-1003 /11 PAGE ii INTENTIONALLY BLANK MIL-HDBK-1003 /11 13 OCTOBER 1987 MILITARY HANDBOOK DIESEL -ELECTRIC GENERATING PLANTS AMSC N/A DISTRIBUTION ... CRITERIA (UFC) GENERAL ELECTRIC GENERATING PLANTS Any copyrighted material included in this UFC is identified at its point of use. Use of the copyrighted materi...
Ngày tải lên: 08/08/2014, 12:21
... . . . . . . . . 22 Section 5 DEFINITIVE DESIGNS FOR DIESEL -ELECTRIC GENERATING PLANTS 5.1 Definitive Diesel -Electric Generating Plants. . . . . . 23 5.1.1 Modifications to NAVFAC Definitive ... BUILDING CONSTRUCTION FOR DIESEL -ELECTRIC GENERATING PLANTS 9.1 Building Construction . . . . . . . . . . . . . . . . . 46 9.2 Single-Level Diesel -Electric Generating Plant...
Ngày tải lên: 08/08/2014, 12:21
GENERAL ELECTRIC GENERATING PLANTS Part 3 pdf
... evaluating third party funding of electric generating facilities, (DEPPM 85-3), c) investigating other electric- generating technology, such as gas turbine-generators versus diesel -electric generation, ... loads, or to generate additional electric power, are addressed. 1.2 Diesel -Electric Generating Plant Types. This handbook addresses stationary diesel -electric generating...
Ngày tải lên: 08/08/2014, 12:21
GENERAL ELECTRIC GENERATING PLANTS Part 4 pot
... guide specifications. 3.3 Duty and Capacity Requirements for Electric Generating Plants. Sources and duty types of electric generating plants are defined in Section 2. Table 2 summarizes capacity ... ownership alternatives. 3.2 Electrical Loads. Electric loads should be determined carefully to size electric generating plant components properly. The duration and variation of...
Ngày tải lên: 08/08/2014, 12:21
GENERAL ELECTRIC GENERATING PLANTS Part 5 docx
... following fuel selections: 26 MIL-HDBK-1003 /11 Section 5: DEFINITIVE DESIGNS FOR DIESEL -ELECTRIC GENERATING PLANTS 5.1 Definitive Diesel -Electric Generating Plants. The Navy has several definitive ... initial bays for standby/emergency duty plants. A future engine-generator bay is indicated for all designs. Most plants will need to be expanded to satisfy future electric l...
Ngày tải lên: 08/08/2014, 12:21
GENERAL ELECTRIC GENERATING PLANTS Part 6 pdf
... provided on most attended electric generating plants. Automatic start up, synchronization, and shutdown is normally only provided for unattended plants. 36 MIL-HDBK-1003 /11 fuel oil centrifuging ... for smaller-sized generating units and capacities of 3 to 5 tons (2,700 to 4,500 kg) are normally adequate for larger-sized engine -generating units. 5.4.14.2 Electric Operation. H...
Ngày tải lên: 08/08/2014, 12:21
GENERAL ELECTRIC GENERATING PLANTS Part 7 docx
... 45 MIL-HDBK-1003 /11 Section 9: BUILDING CONSTRUCTION FOR DIESEL -ELECTRIC GENERATING PLANTS 9.1 Building Construction. Building types which house diesel -electric generating plants are either ... system. For low-voltage generating plants, 24 V or 48 V systems should normally be supplied, except where very small systems utilize automatic transfer switches for commercial to gen...
Ngày tải lên: 08/08/2014, 12:21
GENERAL ELECTRIC GENERATING PLANTS Part 8 docx
... flexibility. 56 MIL-HDBK-1003 /11 9.2 Single-Level Diesel -Electric Generating Plant Layout. The single-story slab-on-grade layout is the usual design for smaller electric- generating plants (1,000 kW capacity ... Material. 12.1.1 Specifications. Use the appropriate NFGS electric generating plant specification to specify all piping materials for diesel electric- generating...
Ngày tải lên: 08/08/2014, 12:21
GENERAL ELECTRIC GENERATING PLANTS Part 9 pptx
... a minimum 200 lb/ftÀ2Ù (976 kg/mÀ2Ù) live load. 66 MIL-HDBK-1003 /11 15.3.1.1 Definitive Designs. In general, a diesel -electric generating type power plant should have two-level-type construction ... MIL-HDBK-1003 /11 Section 13: INSULATION 13.1 Insulation Materials. See Table 14 for characteristics and temperature use limits of insulation materials applicable to diesel -electric g...
Ngày tải lên: 08/08/2014, 12:21