Industrial Control Student Guide Version 1 1 phần 5 ppt

Industrial Control Student Guide Version 1.1 phần 1 pps

Industrial Control Student Guide Version 1.1 phần 1 pps

... On-Off Control 98 Exercise #2: Open-Loop vs. Closed-Loop Control 11 3 Questions and Challenge 12 5 Experiment #5: Closed-Loop Control 12 7 Exercise #1: Establishing Closed-Loop Control 13 0 Exercise ... Differential-Gap Control 13 6 Questions and Challenge 14 2 Experiment #6: Proportional Integral Derivative Control 14 5 Exercise #1: Bias Drive 15 5 Exercise...
Ngày tải lên : 08/08/2014, 01:21
  • 25
  • 365
  • 0
Industrial Control Student Guide Version 1.1 phần 2 pot

Industrial Control Student Guide Version 1.1 phần 2 pot

... hold count Counts = 0 Loop: PAUSE 50 BUTTON 1, 1, 255 ,0,Wkspace1 ,1, Count_it ' Debounced edge trigger detection of PB1 BUTTON 2,0, 255 ,0,Wkspace2 ,1, Clear_it ' Debounced edge trigger ... Figure 2 .5 shows how the program executes. Figure 2 .5: Flowchart for Program 2 .1 Experiment #2: Digital Input Signal Conditioning Industrial Control Version 1...
Ngày tải lên : 08/08/2014, 01:21
  • 25
  • 304
  • 0
Industrial Control Student Guide Version 1.1 phần 3 pot

Industrial Control Student Guide Version 1.1 phần 3 pot

... Experiment #2: Digital Input Signal Conditioning Industrial Control Version 1. 1 • Page 63 Duty Voltage RPM 1 2 3 4 5 6 7 8 9 10 11 12 13 14 StampPlot Lite will plot the speed ... the 1 cycle/second Encoder is an RPM of 50 82 Duration Counts Scaler RPM Resolution 10 00 mS 84 60 50 40 60 RPM 2000 mS 16 9 30 50 70 30 RPM 3000 mS 254 20 50 80 20 RP...
Ngày tải lên : 08/08/2014, 01:21
  • 28
  • 250
  • 0
Industrial Control Student Guide Version 1.1 phần 4 pot

Industrial Control Student Guide Version 1.1 phần 4 pot

... 0.27 10 10 10 11 11 :46 :50 AM 0.32 11 11 11 11 11 :46 :50 AM 0.32 12 12 12 11 11 :46: 51 AM 0.43 13 13 13 11 11 :46: 51 AM 0 .50 14 14 14 11 11 :46: 51 AM 0. 71 15 15 15 11 11 :46: 51 AM 0.98 16 16 16 11 11 :46: 51 ... AM 0. 21 222 11 11 :46 :50 AM 0. 21 333 11 11 :46 :50 AM 0. 21 444 11 11 :46 :50 AM 0.27 55 5 11 11 :46 :50 AM 0.27 666 1...
Ngày tải lên : 08/08/2014, 01:21
  • 29
  • 315
  • 0
Industrial Control Student Guide Version 1.1 phần 5 ppt

Industrial Control Student Guide Version 1.1 phần 5 ppt

... 1. 7 W 1. 7 W 75% 1. 7 W 50 % 0. 85 W 1. 7 W 25% 1. 7 W 0% 0 W Experiment #5: Closed-Loop Control Industrial Control Version 1. 1 • Page 12 7 An open-loop control system can deliver a desired ... 0 - 255 for temps ' of 700 to 12 00 tenths of degrees. LOW 8 ' Initialize heater OFF Experiment #4: Continuous Process Control Industrial Control...
Ngày tải lên : 08/08/2014, 01:21
  • 33
  • 314
  • 0
Industrial Control Student Guide Version 1.1 phần 6 pot

Industrial Control Student Guide Version 1.1 phần 6 pot

... Derivative Control Industrial Control Version 1. 1 • Page 16 1 Figure 6.6: Temperature vs. Drive Over 50 % of Range Temperature vs. Drive 0 10 20 30 40 50 60 70 80 90 10 0 11 0 10 0 10 0 .5 10 1 10 1 .5 10 2 10 2 .5 ... Derivative Control Industrial Control Version 1. 1 • Page 16 7 Figure 6.8b: Message file plotted in Excel Drive with Kp =1 -80 -60 -40...
Ngày tải lên : 08/08/2014, 01:21
  • 29
  • 351
  • 0
Industrial Control Student Guide Version 1.1 phần 7 pps

Industrial Control Student Guide Version 1.1 phần 7 pps

... Hexadecimal 0 0000 0 8 10 00 8 1 00 01 1 9 10 01 9 2 0 010 2 10 10 10 A 3 0 011 3 11 10 11 B 4 010 0 4 12 11 00 C 5 010 1 5 13 11 01 D 6 011 0 6 14 11 10 E 7 011 1 7 15 11 11 F In Binary Coded Decimal, ... Industrial Control Version 1. 1 • Page 16 9 Figure 6.9b: Data File Plotted in Excel Drive with Kp=2 - 15 0 -10 0 -50 0 50 10 0 15 0 200 0...
Ngày tải lên : 08/08/2014, 01:21
  • 29
  • 381
  • 0
Industrial Control Student Guide Version 1.1 phần 8 ppsx

Industrial Control Student Guide Version 1.1 phần 8 ppsx

... Temperature Data 700 7 25 750 7 75 800 8 25 850 8 75 900 22: 51 00: 01 01: 11 02: 21 03: 31 04: 41 05: 51 07: 01 08 :11 09: 21 10: 31 11: 41 12: 51 14: 01 15 :11 16 : 21 17: 31 18: 41 19: 51 21: 01 22 :11 23: 21 00: 31 Time Temperature ... Control Version 1. 1 • Page 207 'Define RTC Constants 'Register values in the RTC SecReg CON %00000...
Ngày tải lên : 08/08/2014, 01:21
  • 24
  • 357
  • 0
Industrial Control Student Guide Version 1.1 phần 9 ppt

Industrial Control Student Guide Version 1.1 phần 9 ppt

... 232 • Industrial Control Version 1. 1 Appendix B: Fan Encoder Printouts Page 234 • Industrial Control Version 1. 1 Appendix A: StampPlot Lite Industrial Control Version 1. 1 • Page 2 31 Upgrade ... Industrial Control Version 1. 1 Appendix D: LM34 Manufacturer’s Datasheet Page 242 • Industrial Control Version 1. 1 Appendix A: StampPlot Lite P...
Ngày tải lên : 08/08/2014, 01:21
  • 22
  • 256
  • 0
Industrial Control Student Guide Version 1.1 phần 10 pdf

Industrial Control Student Guide Version 1.1 phần 10 pdf

... capacitor 1 1 1 1 2 01- 010 50 1uF capacitor 1 1 2 01- 010 60 10 uF 10 V capacitor 1 1 1 1 1 2 51 - 03230 32.768 kHz Clock Crystal 1 1 350 -000 01 LED green 1 1 1 1 350 -00006 LED red 1 1 1 1 1 1 1 350 -00007 ... 3 1 1 1 1 4 15 0-04 710 470 ohm ¼ watt resistor 1 1 1 1 1 4 15 2- 010 31 10K ¼ watt multi-turn pot 1 2 2 2 2 2 2 2 15...
Ngày tải lên : 08/08/2014, 01:21
  • 22
  • 348
  • 0