Power Quality Harmonics Analysis and Real Measurements Data Part 14 docx
... Power Quality Harmonics Analysis and Real Measurements Data 260 Transactions on Power Delivery, Vol. 23, Issue 2, (april 2008), pp. 974-984, ISSN 0885- 8977. CA8334, Three Phase Power Quality ... reactive power and harmonic power, while DPF only includes the fundamental reactive power caused by a phase shift between voltage and fundamental current. Powe...
Ngày tải lên: 19/06/2014, 08:20
... the 14- state model 2. Power Quality Harmonics Analysis and Real Measurements Data 20 Figure 12 –15 give the three algorithms estimates, for 10% missing data with no noise and with 0.1 standard ... of 60 Hz and third harmonic component using the 14- state model 1. Power Quality Harmonics Analysis and Real Measurements Data 14 deviation of t...
Ngày tải lên: 19/06/2014, 08:20
... (101) Power Quality Harmonics Analysis and Real Measurements Data 66 S.A. Soliman, I. Helal, and A. M. Al-Kandari, Fuzzy linear regression for measurement of harmonic components in a power ... the amplitude and phase angles of each harmonic component are time independent, steady state harmonics identification. Power Quality Harmonics Analysis and...
Ngày tải lên: 19/06/2014, 08:20
Power Quality Harmonics Analysis and Real Measurements Data Part 10 docx
... X S ·d C ·Y 2k and X S ·Y Pk , which can be rewritten from (14) as Power Quality Harmonics Analysis and Real Measurements Data 180 force on Harmonic Modeling and Simulation, 2003), and |Z P1 | and ... Power Quality Harmonics Analysis and Real Measurements Data 170 Zhou, L.H., Fu, Q., Liu, C.S.(2009). Modeling and Control Analysis of a Hy...
Ngày tải lên: 19/06/2014, 08:20
Power Quality Harmonics Analysis and Real Measurements Data Part 12 docx
... Hertz waveform, and so on. Power Quality Harmonics Analysis and Real Measurements Data 214 4. Brief steel plant system description The steel plant system consists of 49 buses and 38 two winding ... readings is 28.9%. Moreover, the harmonics appears to distort the phase current waveform as in Figure 6. Power Quality Harmonics Analysis and Real Measur...
Ngày tải lên: 19/06/2014, 08:20
Power Quality Harmonics Analysis and Real Measurements Data Part 15 doc
... wind farm electric circuit and grounding system and (b) FFT analysis of the voltage waveform obtained. Power Quality Harmonics Analysis and Real Measurements Data 278 Chicco G., Schlabbach ... distribution network: (a) phase voltage waveform and (b) FFT analysis of the waveform obtained, at node 5. Power Quality Harmonics Analysis and Real Mea...
Ngày tải lên: 18/06/2014, 22:20
Power Quality Harmonics Analysis and Real Measurements Data Part 1 pdf
... Power Quality Harmonics Analysis and Real Measurements Data, Edited by Gregorio Romero Rey and Luisa Martinez Muneta p. cm. ISBN 978-953-307-335-4 POWER QUALITY HARMONICS ANALYSIS AND ... HARMONICS ANALYSIS AND REAL MEASUREMENTS DATA Edited by Gregorio Romero Rey and Luisa Martinez Muneta Power Quality Harmonics Analysis and R...
Ngày tải lên: 19/06/2014, 08:20
Power Quality Harmonics Analysis and Real Measurements Data Part 3 ppt
... this power) . Examination of these curves reveals the following results. The fundamental power and the fourth and sixth harmonics are time-varying. Power Quality Harmonics Analysis and Real Measurements ... and Measurements 31 recorded data set. and computes the voltage and current harmonics magnitude, the voltage and current harmonics phase angle...
Ngày tải lên: 19/06/2014, 08:20
Power Quality Harmonics Analysis and Real Measurements Data Part 5 doc
... Group , Interharmonics in Power Systems. Power Quality Harmonics Analysis and Real Measurements Data 88 Johnson, R. A. & Wichern, D. W. (2007). Applied Multivariate Statistical Analysis, ... impedance of the transmission and distribution lines, and of the step-down and step-up transformers. Power Quality Harmonics Analysis and Real Measurement...
Ngày tải lên: 19/06/2014, 08:20
Power Quality Harmonics Analysis and Real Measurements Data Part 6 pptx
... transformer for power system harmonic frequencies, IEEE Transactions on Power Delivery, Volume 10, Issue 4, Oct. 1995 Power Quality Harmonics Analysis and Real Measurements Data 92 Wideband analysis ... Power Quality Harmonics Analysis and Real Measurements Data 90 of metering apparatus or protection relays extensively used in power system. VT...
Ngày tải lên: 19/06/2014, 08:20