Programmable logic controllers 5ed P1
... answer options. 1. The term PLC stands for: A. Personal logic computer B. Programmable local computer C. Personal logic controller D. Programmable logic controller 2. Decide whether each of these statements ... PLCs. Summary A programmable logic controller (PLC) is a special form of microprocessor-based controller that uses a programmable memory to store instructions and to im...
Ngày tải lên: 10/04/2014, 14:10
Programmable logic controllers 5ed P2
... concerned. However, with sequential logic systems the output is influenced by the history of the past inputs as well as by the present inputs. Both combinational logic and sequential logic systems are introduced ... 1, and are described as two-state variables or logical variables. The complete system constructed with such variable is termed a logic system or logic gates. If the outp...
Ngày tải lên: 10/04/2014, 14:12
Programmable logic controllers 5ed P3
... a situation involves the AND logic function, condition A and condition B having both to be realized for an output to occur. This section is a consideration of such logic functions. 5.2.1 AND Figure ... have A and B both 1. Such an operation is said to be controlled by a logic gate, and the relationship between the inputs to a logic gate and the outputs is tabulated in a form known as...
Ngày tải lên: 10/04/2014, 14:14
Programmable logic controllers 5ed P4
... NOT 1, the actions following that line in the program are to occur. The IF statement: IF fluid_temp1 OR fluid_temp2 THEN www.newnespress.com IL, SFC, and ST Programming Methods 163 is used to indicate
Ngày tải lên: 10/04/2014, 14:16
Programmable logic controllers 5ed P5
... call is without conditions and is always executed. If there is a logic operation preceding EN, the block call is executed only if the logic condition is fulfilled. In Figure 8.7 this is a closure ... long a particular operation took). The Allen-Bradley timers have three Boolean bits for ladder logic control: a timer enable bit (EN), which goes on when the timer accumulator is incrementi...
Ngày tải lên: 10/04/2014, 14:18
Programmable logic controllers 5ed P6
... structured text we might have: (*Check that boiler pressure P2 is less than pressure P1* ) Output :¼ P2 < P1; With ladder programs, for data comparison the typical instruction will contain the
Ngày tải lên: 10/04/2014, 14:20
Programmable logic controllers 5ed P7
... include a description of the plant, specification of the control requirements, details of the programmable logic controller, electrical installation diagrams, lists of all input and output connections, ... An important standard relevant to PLCs is IEC 61508: Functional Safety of Electrical/Electronic /Programmable Electronic Safety-Related Systems. Emergency stop buttons and safety guard...
Ngày tải lên: 10/04/2014, 14:22
Programmable logic controllers 5ed P8
... and remains true for the pulse duration specified by input PT. TP BOOL TIME BOOL TIME IN PT Q ET Logic Gates AND gate Output A B Inputs & A B Output Inputs OR gate A B Output Inputs Ն1 A B Output Inputs NOT
Ngày tải lên: 10/04/2014, 14:24
... of General Purpose Programmable Controllers. Before using the product, please read this manual carefully to develop full familiarity with the functions and performance of the Programmable Controller ... order of the programs other than the SFC program and their processings. MELSEC System Q Programmable Logic Controllers Programming Manual (MELSAP L) QCPU INDUSTRIAL AUTOMATION MITS...
Ngày tải lên: 15/10/2013, 16:28