1. Trang chủ
  2. » Công Nghệ Thông Tin

Hệ thống ghép kênh VCL

238 761 0

Đang tải... (xem toàn văn)

Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống

THÔNG TIN TÀI LIỆU

Thông tin cơ bản

Định dạng
Số trang 238
Dung lượng 5,07 MB

Nội dung

Tài liệu Hệ thống ghép kênh MUX VCL hi vọng có thể giúp ích cho các bạn, các bạn đọc và chia sẻ đến rộng rãi nếu có thể nhé, cảm ơn các bạn rất nhiều rất nhiều rất nhiều nhiều nhiều ấdasdasdsadsadasdasdasdasdasdasdasdasdasdassdasdaĐASsfsdfssfsdfsfsfdsfsfsdfsdfsdfsfsfsdfsdf

VALIANT COMMUNICATIONS VCL-MX TM Version - E1 Multiplexer User Installation Manual Copyright: Valiant Communications Limited - 2016 Notice VCL-MX Version - E1 Multiplexer Warranty This Valiant product is warranted against defects in material and workmanship for a period of one year from the date of shipment During the warranty period, Valiant will, at its discretion, either repair or replace products, which prove to be defective For warranty service or repair, this product must be returned to a service facility designated by Valiant The buyer shall prepay shipping charges to Valiant and the company shall pay shipping charges to return the product to the buyer However, the buyer shall pay all the shipping charges, duties and taxes for products returned to Valiant from another country Limitation of Warranty The foregoing warranty shall not apply to defects resulting from improper or inadequate maintenance by the buyer The buyer-supplied firmware or interfacing, unauthorized modification or misuse, operation outside of the environmental specifications for the product or improper site preparation or maintenance Exclusive Remedies The remedies provided herein are the buyer's sole and exclusive remedies Valiant shall not be liable for any direct, indirect, special, incidental or consequential damages, whether based on contract or any legal theory Notice This manual contains information that is proprietary to Valiant Communications Limited No part of this publication may be reproduced in any form whatsoever without prior written approval by Valiant Communications Limited Safety Warnings ! The exclamation point within a triangle is intended to warn the operator or service personnel of operation and maintenance factors relating to the product and its operating environment, which could pose a safety hazard Always observe standard safety precautions during installation, operation and maintenance of this product Only qualified and authorized service personnel should carry out adjustment, maintenance or repairs to this instrument No adjustment, maintenance or repairs should be performed by either the operator or the user UALITY ASSURANCE PROGRAM Valiant’s products are designed and manufactured under a strict Quality Assurance Program based on the ISO 9001:2008, 14001:2004 and ISO 10002:2004 philosophy and principles Valiant pays very special attention to its vendor development program which ensures an “end-product” of the highest quality at the most cost effective prices Copyright: Valiant Communications Limited - 2016 Index VCL-MX Version - E1 Multiplexer INDEX Particulars Section 1: System Description and Installation Product Overview Key Features Additional Features Highlights OAM Features Management and Monitoring OAM: Operation and Management Ports Security and Protection Transmission Medium Multi-service platform Configuration and Flexibility Synchronization Clock Application of VCL-MX System Overview and Architectural Details Shelf Description Chassis / System Backplane System Management Section 2: Technical Specifications E1 Interface FXS, Voice Frequency Interface FXO, Voice Frequency Interface Ring Generator Card Power Supply Card Hot-Line Interface Card Low Speed Data Interface Asynchronous RS232 E&M Wire / Wire Voice Frequency Interface 64Kbps Data Interface G703 @ 64kbps, Synchronous Data Interface Relay I/O Interface Card Relay Specifications (Drivers) Dry Contacts Sensors Copyright: Valiant Communications Limited - 2016 P No 10 11 11 12 13 13 13 13 13 14 14 14 14 15 15 16 17 17 18 19 20 21 21 21 22 22 23 23 23 24 24 24 Index VCL-MX Version - E1 Multiplexer INDEX Particulars Universal Data Interface Integrated IEEE C3794 Teleprotection Interface E1 Plus 100Mbps Ethernet Fiber Optical Transport Interface Management Interface Protection Power Consumption Environmental Dimensions P No 24 25 25 26 26 26 26 26 Section 3: Application Diagram and Connection Details Applications Telco Networks Providing Services Applications Diagram System Layout Core System Composition VCL-MX Version - Back View Connection Details Common Connector Pinout Details 27 28 28 28 31 32 33 34 35 Section 4: Card Description and Cabling Details Power Supply Card OAM Card Ring Generator Card Control Card E1 Interface Card Redundant E1 Interface Card FXS (SLC), Voice Frequency Interface Card FXO (JNC), Voice Frequency Interface Card Hotline, Voice Frequency Interface Wire / Wire E&M, Voice Frequency Interface Card G703 Interface Card E1 Plus Fast Ethernet Fiber Optical Transport Interface Card RIO (Relay Input Output) Card 36 37 38 39 40 43 46 51 55 59 63 70 73 75 Copyright: Valiant Communications Limited - 2016 Index VCL-MX Version - E1 Multiplexer INDEX Particulars Low Speed Data Interface 64Kbps Data Interface Card Nx64Kbps Data Interface Card VCL-TP, Command Teleprotection Interface Card 4xIEEE C37.94 Channel Card P No 79 82 89 95 99 Section 5: OAM Description and Setup Rules OAM Default Settings Network Address Settings Default Usernames and Passwords SNMP Settings Description: OAM Card Super User - Definition Assigning a new password User - Definition The OAM Password Strength Standards and Compliance Audit User - Definition Applicable Security Conditions 100 101 101 101 101 102 102 103 103 105 107 107 Section 6: HyperTerminal Settings To use HyperTerminal for executing the CLI commands HyperTerminal settings for COM Port (RS232) and USB Port HyperTerminal settings for 10/100BaseT Management Port Telnet without using HyperTerminal utility Retrieving Log file in text format using Web Browser 109 110 111 117 123 124 Section 7: USB Serial Port Drivers Installing USB Serial Port Drivers 126 127 Section 8: CLI Commands Structure of CLI Command Statements and Conventions OAM / Normal Configuration Mode OAM Interface Configuration Commands To Enter OAM config level To View list of OAM configuration commands 134 135 137 137 137 138 Copyright: Valiant Communications Limited - 2016 Index VCL-MX Version - E1 Multiplexer INDEX Particulars All User Help Commands To Set SNMP Trap Target Port Address To Set SNMP Trap Target Port To Set Trap Target Community To Change Self Password To Check OAM Firmware Version To View OAM Settings To Exit from OAM Configuration Mode To Exit from system To Set System IP Address To Set Subnet Mask To Set Default Gateway To Configure DNS IP Address To Set SNMP Read Community To Set SNMP Write Community To Enable / Disable the SNMP To Add New User To Delete the User To Change the Super User Password To View System User List To View log of all successful Users To View log of all failed attempts To View log of SSH Users To View log of Telnet Users To View log of Serial Port Users To View log of All Authorized Users To Change Audit User password Test Command To View ping result System Commands To View the Available Help Menus Help CLI Structure Menu Control Card Statements Copyright: Valiant Communications Limited - 2016 P No 139 139 139 139 139 140 141 141 141 141 141 141 142 142 142 142 142 143 143 143 143 143 143 144 144 144 144 144 144 145 145 149 151 Index VCL-MX Version - E1 Multiplexer INDEX Particulars To Set the System Factory Default Settings System Default Settings To Check the System Boot Status and Self Test Error To Check the Ringer and Input Power Status To Set / Check the System Clock Priority To Set / Check RTC (Real Time Clock) Settings To Reset System / Interface Card and Check System Configurations To Check the System and Interface Card Status E1 Interface Card Statements To Set Default and Configure the E1 Card To Configure the E1 Card (Framing, Alarms) and Clear Errors To Check E1 Card settings To Add / Remove an E1 Card To Map the E1 Card - E1port to E1 port To Unmap the E1 Card To Check E1 Card Mapping To Set Default and Configure the Tx / Rx Gain of FXS Card To Configure the FXS Card To Check the FXS Card To MAP FXS Card - E1 to FSX To Unmap FXS Card To Set Default and Configure the Tx / Rx Gain of FXO Card To Configure the FXO Card To MAP FXO Card - E1 to FXO To Check the FXO Card To Unmap FXO Card To Set Default and Configure the Tx / Rx Gain of E&M Card To Configure the E&M Card To Check the E&M Card To MAP E&M Card - E1 to E&M To Unmap E&M Card To Configure the VF Card Custom Signaling To Check / Configure Data and Signaling Loopback of RIO Card Copyright: Valiant Communications Limited - 2016 P No 151 151 152 152 153 154 155 156 158 158 159 160 162 163 164 165 165 166 167 170 171 171 172 173 174 177 177 178 179 181 182 183 184 Index VCL-MX Version - E1 Multiplexer INDEX Particulars To Configure Input Sampling / Level and Output Holding / Level of RIO Card To Check the RIO Card To MAP / UNMAP / Remove RIO Card - E1 to RIO To Check / Configure Data and Signaling Loopback of RS232 Card To MAP / UNMAP RS232 Card - E1 to RS232 To Check the RS232 Card To Configure Data/Signaling Loopback and Enable/Disable alarm of G703 Card To Check the G703 Card To MAP / UNMAP G703 Card - E1 to G703 To Set default, Interface type, Configure Data Loopback and clock of 64IF Card To Configure Loopback and clock of 64IF Card To Check the 64IF Card To Check the 64IF Card Signal Status To MAP / UNMAP / Remove 64IF Card - E1 to 64IF Optical Card Statements To Set Default and configure the Framing ( CRC4) To Clear Errors, Configure Frame, Alarms and Enable / Disable CAS To Enable / Disable CAS and configure Loopback To Clear Errors, Configure Frame, Alarms and Enable / Disable CAS To Configure SFP and ALS mode To Configure ALS To Check Card ID, F/W Version, Settings and Boot Result To Check E1 Loopback and E1 Alarms To Check E1 Alarms and LIF Errors To Check Laser Status To Check SFP Settings and ALS Settings To Configure SFP Parameters and Temperature Threshold To Check SFP Voltage and Current Threshold To Check SFP Transmit / Receive Power Alarm and Warning Threshold To Check SFP Temperature, Voltage and Current To Check SFP Receive and Transmit Power To Check SFP warning To Check SFP Alarms To MAP / UNMAP Optical Card - E1 to Optical Card To Add / Remove Optical Card and Check Mapping Copyright: Valiant Communications Limited - 2016 P No 185 186 188 189 190 191 192 193 194 195 196 197 198 199 200 200 201 202 202 203 204 205 206 207 207 208 209 210 211 212 213 214 215 216 217 Index VCL-MX Version - E1 Multiplexer INDEX Particulars TP4 Channel Teleprotection Optical Card MXV6 TP4 Channel Teleprotection IF Card CLI Commands Core Features Settings CLI Default Config Commands CLI Misc Commands CLI Teleprotection Commands CLI RTC Commands CLI Query Statements Commands CLI Commands External Display / Alarms Unit Statements CLI Commands Mapping Statements 4xIEEE C37.94 Channel Card Help Query Statements Settings Statements Description Query Statements - Basic Setting Description Map C37.94 Card - E1 to TP Section 9: Ordering Information VCL-MX E1 Core System (Common Equipment) VCL-MX, User Configurable Interfaces Optional and Accessories Support Copyright: Valiant Communications Limited - 2016 P No 218 218 218 218 219 220 221 222 223 224 225 225 227 228 229 231 232 233 236 238 VCL-MX Version - E1 Multiplexer Section SECTION: System Description and Installation Copyright: Valiant Communications Limited - 2016 10 TP4 Channel Teleprotection Card VCL-MX Version - E1 Multiplexer CLI Commands Mapping Statements PROMPT: MXV6> S No Command Statements {prompt}> Response Remarks OK Map E1 Card in Slot 'SS' Port 'NN' to Time Slots 'EE-FF' to TP4 Card in Slot 'TT OK Un-Map TP4 Card in Slot 'TT OK Display TP4 Card in Slot-TT Mapping OK Remove Configured Card TP4 map/e1/SS/NN/EE-FF=tp4/TT 'SS' is E1 Card Slot [01-10] 'NN' = 01 to 08 EE,FF =01,02, ,31 {E1 tslots} EE is less than or equal to FF EE-FF should be tslots 'TT'=02 to 10 [TP4 IF Card slot No.] {prompt}> unmap/tp4/TT 'TT'=02 to 10 [TP4 IF Card slot No.] {prompt}> mapping/tp4/TT? 'TT'=02 to 10 [TP4 IF Card slot No.] {prompt}> remove/card/SS 'SS'=02 to 10 [TP4 IF Card slot No.] Copyright: Valiant Communications Limited - 2016 224 VCL-MX Version - E1 Multiplexer C37.94 Interface Card Help Query Statements (help?, help_basic? Etc.) The “help?” query statement shall display all help sub-menus All the help menus are viewable in both Operational as well as Configuration modes PROMPTS: STM1CONVS> Normal Operational Mode Prompt S No Command Statements {prompt}> help/tpa?? Response Remarks Inactive: CC [Slot-2] Response: Active CC [Slot-1] Response: TP CARD STMTS(PAGE-A) setdef/SS data/loopback/tp/SS/PP=on, off sig/loopback/tp/SS/PP=on, off tp/alarms/SS/PP/en or dis tp/fx1/SS/PP/en or dis tp/fx2/SS/PP/en or dis clear/errors/tp/SS/all clear/errors/tp/SS/PP SS=02 to 10, [TP IF Card slot No.] PP=01 to 04 [TP IF Card Port No.] Displays the help query statements of various categories The help sub-menus list all the categories of possible CLI statements syntax supported by the system from operational as well as configuration level prompts {prompt}> help/tpb? Inactive: CC [Slot-2] Response: Active CC [Slot-1] Response: TP CARD STMTS(PAGE-B) Following are the query statements : card/SS? ver/SS? test/SS? settings/tp/SS? card/loop/tp/SS? alarms/tp/SS? errors/tp/SS/PP? SS=02 to 10, [TP IF Card slot No.] PP=01 to 04 [TP IF Card Port No.] Displays the help query statements of C37.94 card {prompt}> help/map/tp? Inactive: CC [Slot-2] Response: Active CC [Slot-1] Response: E1 to TP Card Mapping/Un-mapping STATEMENTS map/e1/SS/NN/PP=tp/min/TT/XX map/e1/SS/NN/EE-FF=tp/max/TT/XX map/e1/SS/NN/PP=tp/TT/XX/AA map/e1/SS/NN/PP-QQ=tp/TT/XX/AA-BB map/e1/SS/NN=tp/full/TT/XX unmap/tp/TT/XX unmap/tp/TT/XX/AA mapping/tp/TT/XX? remove/card/SS SS=01 to 10 [E1 IF Card slot No.] TT=02 to 10 [TP IF Card slot No.] NN=01-08 {E1 IF Port} PP,QQ,EE,FF =01,02, ,31 {E1 tslots} XX=01 to 04 [TP IF Card Port No.] AA,BB=02, ,31 {TP tslots} EE is less than or equal to FF and EE-FF should be tslots PP,AA is less than or equal to QQ,BB Displays the help query statements of category: “Mapping” Copyright: Valiant Communications Limited - 2016 225 C37.94 Interface Card VCL-MX Version - E1 Multiplexer Help Query Statements (help?, help_basic? Etc.) The “help?” query statement shall display all help sub-menus All the help menus are viewable in both Operational as well as Configuration modes PROMPTS: STM1CONVS> Normal Operational Mode Prompt S No Command Statements {prompt}> setdef/SS {enter} SS=02 to 10, [TP IF Card slot No.] {prompt}> data/loopback/tp/SS/PP= {option} {enter} Option = on, off Response Remarks Inactive: CC [Slot-2] Response: Active CC [Slot-1] Response: OK Wait for 60secs Approx then type test/SS? Set C37.94 Card in Slot SS settings to factory default Inactive: CC [Slot-2] Response: Active CC [Slot-1] Response: Set TP Card in Slot SS CARD level loopback for data 'on' means all data timeslots are looped back to system E1 channels to which it is mapped 'off' means no loopback (normal operation) OK SS=02 to 10, [TP IF Card slot No.] PP=01 to 04 [TP IF Card Port No.] {prompt}> sig/loopback/tp/SS/PP= {option} {enter} Option = on, off Inactive: CC [Slot-2] Response: Active CC [Slot-1] Response: OK SS=02 to 10, [TP IF Card slot No.] PP=01 to 04 [TP IF Card Port No.] Copyright: Valiant Communications Limited - 2016 Set TP Card in Slot SS CARD level loopback for signaling 'on' means all sig timeslots are looped back to system E1 channels to which it is mapped 'off' means no loopback (normal operation) 226 C37.94 Interface Card VCL-MX Version - E1 Multiplexer Setting Statements Description PROMPTS: STM1CONVS> Normal Operational Mode Prompt S No Command Statements Response {prompt}> tp/alarms/SS/PP/en or dis Inactive: CC [Slot-2] Response: Active CC [Slot-1] Response: SS=02 to 10, [TP IF Card slot No.] PP=01 to 04 [TP IF Card Port No.] OK {prompt}> tp/fx1/SS/PP/en or dis Inactive: CC [Slot-2] Response: Active CC [Slot-1] Response: SS=02 to 10, [TP IF Card slot No.] PP=01 to 04 [TP IF Card Port No.] OK {prompt}> tp/fx2/SS/PP/en or dis Inactive: CC [Slot-2] Response: Active CC [Slot-1] Response: SS=02 to 10, [TP IF Card slot No.] PP=01 to 04 [TP IF Card Port No.] OK {prompt}> clear/errors/tp/SS/all Inactive: CC [Slot-2] Response: Active CC [Slot-1] Response: SS=02 to 10, [TP IF Card slot No.] OK {prompt}> clear/errors/tp/SS/PP Inactive: CC [Slot-2] Response: Active CC [Slot-1] Response: SS=02 to 10, [TP IF Card slot No.] PP=01 to 04 [TP IF Card Port No.] Copyright: Valiant Communications Limited - 2016 Remarks Enables or disables the alarms of C37.94 IF Card in Slot SS Enables Transmit of AIS on TP i/f output port on LOSS of Signal at the Port Receive Input Enables Transmit of AIS on TP i/f output port on LOSS of Signal at the REMOTELY MAPPED TP Port Receive Input Clears Error Counters of all TP Ports of C37.94 in Slot-SS Clears CRC Error Counters of TP Port SS/NN 227 C37.94 Interface Card VCL-MX Version - E1 Multiplexer Query Statements - Basic Setting Description PROMPTS: STM1CONVS> Normal Operational Mode Prompt S No Command Statements {prompt}> card/SS? {enter} SS=02 to 10, [TP IF Card slot No.] {prompt}> ver/SS? {enter} SS=02 to 10, [TP IF Card slot No.] {prompt}> alarms/tp/SS? enter} SS=02 to 10, [TP IF Card slot No.] {prompt}> test/SS? {enter} SS=02 to 10, [TP IF Card slot No.] {prompt}> settings/tp/SS? {enter} SS=02 to 10, [TP IF Card slot No.] {prompt}> card/loop/tp/SS? {enter} SS=02 to 10, [TP IF Card slot No.] Response Remarks Inactive: CC [Slot-2] Response: Active CC [Slot-1] Response: Slot-SS, IF Card Type : C37.94 x4 Response of Card: Card name Inactive: CC [Slot-2] Response: Active CC [Slot-1] Response: F/W : Ver X.Y Response of system: Release firmware version For example Ver 2.00 14JUL14 1200HRS Inactive: CC [Slot-2] Response: Active CC [Slot-1] Response: TP Alarms Status, Card-SS : Port : C3794 ALARM : **LOS **LOS **LOS **LOS E1 LOS : **LOS **LOS **LOS **LOS Remote SYS : - - - - Inactive: CC [Slot-2] Response: Active CC [Slot-1] Response: OVERALL RESULT : PASS Step 1: PASS (Settings) Step 2: PASS (LOGIC) Response indicates the summary sync/alarm status of TP ports {Sync Status}is one of the following: SYNC NO_SYNC** {Alarm Status}is one of the following:: NO_ALARM ALARM** Displays the most recent SYSTEM BOOT-UP diagnostics tests results Inactive: CC [Slot-2] Response: Active CC [Slot-1] Response: TP Settings, Card-SS : Port : Alarms : En En En En Function-1 : En En En En Function-2 : En En En En One of possible responses indicates configured option of TP card setting Inactive: CC [Slot-2] Response: Active CC [Slot-1] Response: TP Card Loopback Settings, CardSS : Port : Data Loop : On Off Off Off Sig Loop : Off Off Off Off Displays Loop-back status Copyright: Valiant Communications Limited - 2016 {loop opt}is [on, off] 228 C37.94 Interface Card VCL-MX Version - E1 Multiplexer To MAP C37.94 Card - E1 to TP PROMPT: MXV6> Help Menu: help/map/fxs? S No Command Statements {prompt}> map/e1/SS/NN/PP=tp/min/TT/XX {enter} Response OK SS=01 to 10 [E1 IF Card slot No.] TT=02 to 10 [TP IF Card slot No.] NN=01-08 {E1 IF Port} PP,QQ,EE,FF =01,02, ,31 {E1 tslots} XX=01 to 04 [TP IF Card Port No.] AA,BB=02, ,31 {TP tslots} EE is less than or equal to FF and EE-FF should be tslots PP,AA is less than or equal to QQ,BB {Prompt}> map/e1/SS/NN/EE-FF=tp/max/TT/XX {enter} {prompt}> mapping/fxs/TT? {Enter} TT=02 to 10 [VF IF Card slot No.] MAPs transmit and received data of timeslot 'PP' of E1 Port 'SS/NN', to received and transmit data of TP Interface card in slot TT port XX Selects the minimum timeslot mapping mode In this mode the TPS-C37.94 system uses only one 64Kbps Timeslot, i.e., the first Timeslot in the payload section of C37.94 OK Selects the maximum timeslot mapping mode In this mode the TPS-C37.94 system uses x 64Kbps Timeslots, i.e., the first six Timeslots in the payload section of C37.94 SS=01 to 10 [E1 IF Card slot No.] TT=02 to 10 [TP IF Card slot No.] NN=01-08 {E1 IF Port} PP,QQ,EE,FF =01,02, ,31 {E1 tslots} XX=01 to 04 [TP IF Card Port No.] AA,BB=02, ,31 {TP tslots} EE is less than or equal to FF and EE-FF should be tslots PP,AA is less than or equal to QQ,BB Remarks MAPs transmit and received data of timeslots in range 'EE-FF' of E1 Port 'SS/NN', to received and transmit data of port 'XX' of Interface card in slot TT Note: - Ranges 'PP-QQ' and “AA-BB' should have identical size i.e difference between 'QQ” and 'PP' should be equal to difference between 'BB' and 'AA' Slot-TT, VF IF Mapping: 01=xxxx 02=xxxx 03=xxxx 04=xxxx 05=xxxx 06=xxxx 07=xxxx 08=xxxx 09=xxxx 10=xxxx 11=xxxx 12=xxxx 13=xxxx 14=xxxx 15=xxxx 16=xxxx Copyright: Valiant Communications Limited - 2016 MAPs transmit and received data of timeslot 'PP' of E1 Port 'SS/NN', to received and transmit data of FXS Interface card in slot TT Channel AA Note: E1 Port is required to be PCM30 229 C37.94 Interface Card VCL-MX Version - E1 Multiplexer S No Command Statements {prompt}> unmap/tp/TT/XX {enter} Response Remarks OK UNMAP System timeslots of some E1 PORT which have been previously mapped to TP interface in slot TT channels AABB Status of these timeslots is set to 'unequipped' OK UNMAP System timeslots of some E1 PORT which have been previously mapped to TP interface in slot TT channels AA Status of these timeslots is set to 'unequipped' Copyright: Valiant Communications Limited - 2016 230 TT=02 to 10 [VF IF Card slot No.] XX=01,02, ,04 {TP IF timeslots} {prompt}> unmap/tp/TT/XX/AA {enter} TT=02 to 10 [VF IF Card slot No.] XX=01,02, ,04 {TP IF timeslots} VCL-MX Version - E1 Multiplexer Section SECTION: Ordering Information and Support Copyright: Valiant Communications Limited - 2016 231 VCL-MX Version - E1 Multiplexer Ordering Information Ordering Information VCL-MX E1 Core System (Common Equipment) S No Part # VCL-MX-1500 VCL-MX-1510 VCL-OAM-2104-5.0 VCL-MX-1506 Product Description E1 Control Card Central processor, cross-connect and system control Card may be used in a + redundant Configuration Note: Please order numbers for + redundancy (-) 48V DC Input Power Supply Card may be used in a 1+1 redundant Configuration Note: Please order numbers for + redundancy Management Card [SNMP, Telnet (RJ45 Port) and Serial Port (USB and DB-9 COM Port)], OAM - Operations and Management Card for connecting the multiplexer to be managed in a LAN - allows the USER to assign a unique IP adress to each multiplexer connected in a LAN to be managed from a single point Telnet, SNMP (V2) 19" Shelf 6U High (Sub-Rack) fitted with 75Ω / 120Ω DB25 (F) Connectorised Backplane Max Ten (10) traffic slots meant for tributary cards (line cards) Copyright: Valiant Communications Limited - 2016 232 VCL-MX Version - E1 Multiplexer Ordering Information VCL-MX, User Configurable Interfaces S No Part # VCL-MX-1520-E1-5.0 VCL-MX-1525-16-5.0 VCL-MX-1525HTL-16-5.0 VCL-MX-1530-16-5.0 VCL-MX-1535-08-5.0 VCL-MX-1540-15 VCL-MX-1540-30 VCL-MX-1526-15R VCL-MX-1526-30R Product Description E1 Interface Card Full capability to cross connect at DS-0, 64Kbps time-slot level as well as to inter-connect to voice and digital data services between 80 incoming E1 Ports (i.e., 80 separate E1 Links, 2480 DS-0 – any to any time-slot cross-connect) (For 8E1 Redundancy please order Cards each Chassis) 16 Port VF, RT (FXS) Line Interface Card 64Kbps/Sec VF Channels per Remote Terminal Line Card (Programmable Tx and Rx settings / VF range -30 dB to +3dB in steps of 0.5dB) (9 Cards / 144 Ports (Max) per Chassis) 16 Port VF, Hot-Line (FXS-Ring-Down) Line Interface Card:, 64Kbps/Sec Hot-Line Channels per Card (Programmable Tx and Rx settings / VF range -30 dB to +3dB in steps of 0.5 dB) (9 Cards / 144 Ports (Max) per Chassis) 16 Port VF, CO (FXO) Line Interface Card 64Kbps/Sec VF Channels per Central Office Line Card (Programmable Tx and Rx settings / VF range -30 dB to +3dB in steps of 0.5 dB) (9 Cards / 144 Ports (Max) per Chassis) Port, VF, E&M Wire / Wire Interface Card 64Kbps/Sec (Programmable Tx and Rx settings / VF range -30 dB to +7dB in steps of 0.5 dB) (09 cards / 72 Ports (Max) per Chassis) Ring Generator Card (15 Watt) Central Office Ring Generator (75 volts RMS) [Supports up to x 16 Port VF, FXS Cards] (To be ordered with FXS card (s) - one card per Chassis) Ring Generator Card (30 Watt) Central Office Ring Generator Card (75 volts RMS) [Supports up to x 16 Port VF, FXS Cards] (To be ordered with FXS card (s) - one card per Chassis) 1+1 Redundant Ring Generator Card (15 Watt x 2) Central Office Ring Generator (75 volts RMS) [Supports up to x 16 Port VF, FXS Cards] (To be ordered with FXS card(s) - one Ringer card per Chassis) 1+1 Redundant Ring Generator Card (30 Watt x 2) Central Office Ring Generator (75 volts RMS) [Supports up to x 16 Port VF, FXS Cards] (To be ordered with FXS card(s) - one Ringer card per chassis) Copyright: Valiant Communications Limited - 2016 233 VCL-MX Version - E1 Multiplexer Ordering Information VCL-MX, User Configurable Interfaces S No Part # 10 VCL-MX-1545-04-48 11 12 13 14 15 16 17 18 19 Product Description Port, 64Kbps DCE [V.35 or V.36 or X.21 or RS530 or V.11 or V.28] Synchronous OR [RS232 or RS485] Asynchronous Data Interface Card with Sub Rate Multiplexing (9 Cards / 36 Ports (Max) per Chassis) VCL-MX-1547-16-48 16 Port, Relay I/O Interface Card (RIO) [Extend either Dry Relay Contacts (Relay Normally-Open or Relay Normally-Close) or operate switches remotely (using Dry Relay Contacts rated 2A @ 30Volts DC) between any two Multiplexers using a 64 Kbps time-slot] (9 Cards / 72 Ports (Max) per Chassis) VCL-MX-1550-04-5.0 Port: 2B+D, Basic Rate ISDN Interface Card, 2B1Q Line Coding, U Interface (4 Ports BRI ISDN Interfaces per card) 09 cards / 36 ports (Max) per Chassis VCL-MX-1551-5.0 E1 Plus Ethernet [100Mbps, Electrical RJ45 (F)] over Fiber Optical Transport Interface Card [2 x SFP based / without SFPs] (without SFPs - SFPs must be ordered separately) (9 Cards / 72 Ports (Max) per Chassis) VCL-MX-1558-04-48 Port, “n x 64” High Speed 64 Kbps to 1920 Kbps (User Configurable) DCE/DTE Synchronous Universal Data Interface Card [DCE/DTE (User programmable for DTE/DCE mode)] [V.35, V.36, X.21, V.11, RS442, RS530] (9 Cards / 36 Ports (Max) per Chassis) VCL-MX-1558-04-48AHS Port, High Speed RS232, RS485, V.24 (V.24/V.28 Line Drivers) 50bps to 115.2Kbps, DTE / DCE Asynchronous Data Interface Card (9 Cards / 72 Ports (Max) per Chassis) VCL-MX-1559-08-5.0 Port, RS232 (V.24/V.28 Line Drivers) 50bps to 19.2Kbps DCE Asynchronous Data Interface Card (9 Cards / 72 Ports (Max) per Chassis) VCL-MX-1560-08-5.0 Port G.703 @ 64Kbps, Synchronous Co-directional Data Interface Card (9 Cards / 72 Ports (Max) per Chassis) VCL-MX-1561-02-5.0 Dual Link O/E Ethernet {Electrical [RJ45 (F)] + Optical [SFP based / without SFP]}Card [for Point-to-Multi Point applications] User configurable from 64Kbps to 2Mbps User Selectable Data Transfer Rate (Max bandwidth per card 2Mbps.) (9 Cards / 36 Ports (Max) per Chassis) VCL-MX-1587-16 16 Port Magneto (GEN-GEN) Line Interface Card (9 Cards / 144 Ports (Max) per Chassis) Copyright: Valiant Communications Limited - 2016 234 VCL-MX Version - E1 Multiplexer Ordering Information VCL-MX, User Configurable Interfaces S No Part # 20 VCL-MX-1590-05 21 VCL-MX-1595-04-5.0 Product Description Port Conference Card 18 x five-way / 30 x three-way multi port voice conference capability (9 Cards / 36 Ports (Max) per Chassis) Port Ethernet [10/100BaseT, Electrical] Card [for Point-to-Point applications] User configurable from 64Kbps to 2Mbps User Selectable Data Transfer Rate (Max bandwidth per card 2Mbps.) (9 Cards / 36 Ports (Max) per Chassis) Copyright: Valiant Communications Limited - 2016 235 VCL-MX Version - E1 Multiplexer Ordering Information Optional and Accessories S No Part # Product Description VCL-1505-TER-DB37F- 16xE1/T1, DB37 [2 x DB37F] to RJ45 [16 x RJ45F] Termination RJ45F-16PP Panel 19" Metal case 1U High Rack Mount Version with Hardware Set [Includes: DB37M-DB37M Cables] [RJ45 cables not included] VCL-1505-TER-DB37F- 32xE1/T1, DB37 [4 x DB37F] to RJ45 [32 x RJ45F] Termination RJ45F-32PP Panel 19" Metal case 1U High Rack Mount Version with Hardware Set [Includes: DB37M-DB37M Cables] [RJ45 cables not included] VCL-1505-TER-DB37F- 48xE1/T1, DB37 [6 x DB37F] to RJ45 [48 x RJ45F] Termination RJ45F-48PP Panel 19" Metal case 1U High Rack Mount Version with Hardware Set [Includes: DB37M-DB37M Cables] [RJ45 cables not included] VCL-1514_1513-TER16xE1, DB37 [2 x DB37F] to BNC [32 x BNCF] Termination DB37F-BNCF-16PP Panel 19" Metal case 1U High Rack Mount Version with Hardware Set [Includes: DB37M-DB37M Cables] [BNC cables not included] VCL-HRNS 1264-4E1O E1/T1 Port Connectorized Cable [DB25M-Open] [1 cable each Port E1/T1 card] VCL-HRNS 1268 E1/T1 Port Connectorized Cable [2xDB25M-DB37M] -8E1Y37M [1 cable each Port VCL-1505-TER-DB37F-RJ45F-16PP] VCL-HRNS 1247-03M 75 Ohms Connectorized Cable [BNCM-BNCM, meter] VCL-HRNS 1247-05M 75 Ohms Connectorized Cable [BNCM-BNCM, meter] VCL-HRNS 1247-10M 75 Ohms Connectorized Cable [BNCM-BNCM, 10 meter] 10 VCL-HRNS 1264FXO FXS/FXO Port Connectorized Cable [DB25M-Open] [1 cable each Port FXS/FXO card] 11 VCL-HRNS 1264ENO E&M Port Connectorized Cable [DB25M-Open] [1 cable each Port E&M card] Copyright: Valiant Communications Limited - 2016 236 VCL-MX Version - E1 Multiplexer Ordering Information Optional and Accessories S No Part # 12 VCL-HRNS 1264RS2V2ORev1 13 VCL-HRNS 1264RIOO 14 VCL-HRNS 1073V35F 15 VCL-HRNS 1075V35M 16 VCL-HRNS 1083V36F 17 VCL-HRNS 1083V36M 18 VCL-HRNS 1084X21F 19 VCL-HRNS 1084X21M 20 22 VCL-HRNS 1082RS5V1O VCL-HRNS 1082RS5V1F VCL-HRNS 1264RSO 23 VCL-HRNS 1264RS9F 24 VCL-HRNS 1264RS9M 25 VCL-HRNS 1264G7O 26 UMIKitMXV6 21 Product Description RS232/V.28 Port 64Kbps Connectorized Cable [DB25M-Open] [1 cable each 1Port RS232/V.28 64Kbps card] RIO Port Drive Connectorized Cable [DB25M-Open] [4 cable each Port RIO card] V.35 Port Connectorized Cable [DB25M-Winchester F] [1 cable each Port V.35 card] OR V.35 Port Connectorized Cable [DB25M-Winchester M] [1 cable each Port V.35 card] V.36 Port Connectorized Cable [DB25M-DB37F] [1 cable each Port V.36 card] OR V.36 Port Connectorized Cable [DB25M-DB37M] [1 cable each Port V.36 card] X.21 Port Connectorized Cable [DB25M-DB25F] [1 cable each Port X.21 card] OR X.21 Port Connectorized Cable [DB25M-DB25M] [1 cable each Port X.21 card] RS530/V.11 Port Connectorized Cable [DB25M-Open] [1 cable each Port RS530/V.11 card] RS530/V.11 Port Connectorized Cable [DB25M-DB25F] [1 cable each Port RS530/V.11 card] RS232 Port Connectorized Cable [DB25M-Open] [1 cable each Port RS232 card] OR RS232 Port Connectorized Cable [DB25M-2xDB9F] [1 cable each Port RS232 card] OR RS232 Port Connectorized Cable [DB25M-2xDB9M] [1 cable each Port RS232 card] G.703 Port Connectorized Cable [DB25M-Open] [1 cable each Port G.703 card] System Core Cables, Blank Space Blocking Plates, Installation Accessories, Documentation, System User Manual / Disk, etc [Set] Copyright: Valiant Communications Limited - 2016 237 Support VCL-MX Version - E1 Multiplexer Note: Note: Operation and maintenance of network equipment require professional knowledge and experience We recommend the equipment to be managed only by qualified technicians Should you require technical assistance please consult the provider, or contact our SUPPORT DESK at support@valiantcom.com Technical specifications are subject to changes without notice All brand names and trademarks are the property of their respective owners Revision 10 – March 21, 2016 Valiant Communications (UK) Ltd 1, Acton Hill Mews, 310-328 Uxbridge Road, London W3 9QN, United Kingdom Website: http://www.valiantcom.com Copyright: Valiant Communications Limited - 2016 Valiant Communications Limited 71/1, Shivaji Marg, New Delhi-110015, India Website: http://www.valiantcom.com 238 ... Exchange E1s VCL- MX Version VCL- MX Version Up to 144 FXS Copyright: Valiant Communications Limited - 2016 28 Application Diagrams VCL- MX Version - E1 Multiplexer Application Side from Exchange VCL- MX... Exchange VCL- MX Version VCL- MX Version Up to 144 FXS E1s E1s VCL- STM-1 Add-Drop Multiplexer STM-1 (SDH) VCL- STM-1 Add-Drop Multiplexer Application Upto 144 Lines Upto 144 Lines VCL- MX Version (with... ODF VCL- MX Version 5xE1 (with FXO Card) Upto 288 Lines Upto 144 Lines Copyright: Valiant Communications Limited - 2016 VCL- MX Version (with FXS Card) Exiting MUX 5xE1 MDF Upto 288 Phone Lines VCL- MX

Ngày đăng: 09/03/2019, 16:21

TỪ KHÓA LIÊN QUAN

w