1. Trang chủ
  2. » Kỹ Thuật - Công Nghệ

Bsi bs en 61643 351 2017

32 2 0

Đang tải... (xem toàn văn)

Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống

THÔNG TIN TÀI LIỆU

Thông tin cơ bản

Định dạng
Số trang 32
Dung lượng 2,59 MB

Nội dung

BS EN 61643-351:2017 BSI Standards Publication Components for low-voltage surge protective devices Part 351: Performance requirements and test methods for telecommunications and signalling network surge isolation transformers (SIT) BRITISH STANDARD BS EN 61643-351:2017 National foreword This British Standard is the UK implementation of EN 61643-351:2017 It is identical to IEC 61643-351:2016 The UK participation in its preparation was entrusted by Technical Committee PEL/37, Surge Arresters - High Voltage, to Subcommittee PEL/37/1, Surge Arresters - Low Voltage A list of organizations represented on this committee can be obtained on request to its secretary This publication does not purport to include all the necessary provisions of a contract Users are responsible for its correct application © The British Standards Institution 2017 Published by BSI Standards Limited 2017 ISBN 978 580 85903 ICS 33.040.99 Compliance with a British Standard cannot confer immunity from legal obligations This British Standard was published under the authority of the Standards Policy and Strategy Committee on 28 February 2017 Amendments/corrigenda issued since publication Date Text affected BS EN 61643-351:2017 EUROPEAN STANDARD EN 61643-351 NORME EUROPÉENNE EUROPÄISCHE NORM February 2017 ICS 33.040.99 English Version Components for low-voltage surge protective devices Part 351: Performance requirements and test methods for telecommunications and signalling network surge isolation transformers (SIT) (IEC 61643-351:2016) Composants pour parafoudres basse tension Partie 351: Exigences de performance et méthodes d'essai pour les transformateurs d'isolement contre les surtensions dans les réseaux de signalisation et de télécommunications (IEC 61643-351:2016) Bauelemente für Überspannungsschutzgeräte für Niederspannung - Teil 351: Leistungsanforderungen sowie Prüfschaltungen und -verfahren für Blitzisoliertransformatoren in Telekommunikations- und signalverarbeitenden Netzen (IEC 61643-351:2016) This European Standard was approved by CENELEC on 2016-12-02 CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CENELEC member This European Standard exists in three official versions (English, French, German) A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom European Committee for Electrotechnical Standardization Comité Européen de Normalisation Electrotechnique Europäisches Komitee für Elektrotechnische Normung CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels © 2017 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members Ref No EN 61643-351:2017 E BS EN 61643-351:2017 EN 61643-351:2017 European foreword The text of document 37B/155/FDIS, future edition of IEC 61643-351, prepared by SC 37B “Specific components for surge arresters and surge protective devices” of IEC/TC 37 “Surge arresters" was submitted to the IEC-CENELEC parallel vote and approved by CENELEC as EN 61643-351:2017 The following dates are fixed: • latest date by which the document has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2017-09-02 • latest date by which the national standards conflicting with the document have to be withdrawn (dow) 2019-12-02 Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights CENELEC [and/or CEN] shall not be held responsible for identifying any or all such patent rights Endorsement notice The text of the International Standard IEC 61643-351:2016 was approved by CENELEC as a European Standard without any modification In the official version, for Bibliography, the following notes have to be added for the standards indicated: IEC 60060-1:2010 NOTE Harmonized as EN 60060-1:2010 (not modified) IEC 60068-2-1:2007 NOTE Harmonized as EN 60068-2-1:2007 (not modified) IEC 60068-2-2:2007 NOTE Harmonized as EN 60068-2-2:2007 (not modified) IEC 60076-1 NOTE Harmonized as EN 60076-1 IEC 60721-3-9:1993 NOTE Harmonized as EN 60721-3-9:1993 (not modified) IEC 61340-4-8 NOTE Harmonized as EN 61340-4-8 IEC 61558-1 NOTE Harmonized as EN 61558-1 IEC 61558-2-4 NOTE Harmonized as EN 61558-2-4 IEC 61558-2-6 NOTE Harmonized as EN 61558-2-6 BS EN 61643-351:2017 EN 61643-351:2017 Annex ZA (normative) Normative references to international publications with their corresponding European publications The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application For dated references, only the edition cited applies For undated references, the latest edition of the referenced document (including any amendments) applies NOTE When an International Publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies NOTE Up-to-date information on the latest versions of the European Standards listed in this annex is available here: www.cenelec.eu Publication Year Title IEC 60721-3-3 - Classification of environmental conditions - EN 60721-3-3 - Part 3: Classification of groups of environmental parameters and their severities Section 3: Stationary use at weatherprotected locations - Insulation coordination for equipment within low-voltage systems Part 2-1: Application guide - Explanation of the application of the IEC 60664 series, dimensioning examples and dielectric testing - IEC/TR 60664-2-1 2011 EN/HD Year –2– BS EN 61643-351:2017 IEC 61643-351:2016 © IEC 2016 CONTENTS FOREWORD INTRODUCTION Scope Normative references Terms, definitions, symbols, abbreviations and acronyms 3.1 Terms and definitions 3.2 Symbols 10 3.3 Abbreviations and acronyms 12 Service conditions 12 4.1 Temperature range 12 4.2 Humidity 12 4.3 Altitude 12 4.4 Microclimate 12 SIT surge conditions 13 5.1 SIT surge mitigation 13 5.2 Common-mode surges 14 5.3 Differential-mode surges 14 Characteristics 15 6.1 Characteristic measurement 15 6.2 Input winding to output winding capacitance 15 6.3 Insulation resistance (IR) 16 6.4 Signal SIT voltage-time product 18 Ratings 19 7.1 Rated impulse withstand voltage 19 7.2 Signal SIT rated winding direct current 22 Identification 24 8.1 8.2 8.3 Annex A General 24 Datasheet 24 Marking 24 (informative) 1,2/50 impulse 25 Bibliography 26 Figure – Symbol for two-winding SIT 10 Figure – Symbol for a two-winding SIT with polarity indication 11 Figure – Symbol for a two-winding SIT with electric screen 11 Figure – SIT with centre tapped windings 11 Figure – Common-mode surge conditions for SIT 13 Figure – Common-mode surge conditions for SIT with an electric screen 14 Figure – Test circuit to measure SIT internal-winding capacitance 15 Figure – Test circuit to measure the internal-winding capacitance of SIT with an electric screen 16 Figure – Test circuit to measure the insulation resistance of SIT 17 Figure 10 – Test circuit to measure the insulation resistance of SIT with an electric screen 17 Figure 11 – Test circuit to measure SIT voltage-time product 18 BS EN 61643-351:2017 IEC 61643-351:2016 © IEC 2016 –3– Figure 12 – Generator and SIT secondary voltage waveforms 18 Figure 13 – SIT rated impulse voltage test circuit 19 Figure 14 – Rated impulse voltage test circuit for SIT with an electric screen 20 Figure 15 – Construction of pass/fail template from the 1,2/50 open-circuit waveform 20 Figure 16 – Pass/fail template and test waveforms 21 Figure 17 – Winding conductor temperature rise test circuit 23 Figure A.1 – 1,2/50 time periods and voltage amplitudes 25 Table – Classification of microclimate condition 12 Table – Impulse withstand test voltage for rated impulse voltage 22 Table A.1 – 1,2/50 voltage impulse generator parameters 25 BS EN 61643-351:2017 IEC 61643-351:2016 © IEC 2016 –4– INTERNATIONAL ELECTROTECHNICAL COMMISSION COMPONENTS FOR LOW-VOLTAGE SURGE PROTECTIVE DEVICES – Part 351: Performance requirements and test methods for telecommunications and signalling network surge isolation transformers (SIT) FOREWORD 1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising all national electrotechnical committees (IEC National Committees) The object of IEC is to promote international co-operation on all questions concerning standardization in the electrical and electronic fields To this end and in addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC Publication(s)”) Their preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with may participate in this preparatory work International, governmental and nongovernmental organizations liaising with the IEC also participate in this preparation IEC collaborates closely with the International Organization for Standardization (ISO) in accordance with conditions determined by agreement between the two organizations 2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international consensus of opinion on the relevant subjects since each technical committee has representation from all interested IEC National Committees 3) IEC Publications have the form of recommendations for international use and are accepted by IEC National Committees in that sense While all reasonable efforts are made to ensure that the technical content of IEC Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any misinterpretation by any end user 4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications transparently to the maximum extent possible in their national and regional publications Any divergence between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in the latter 5) IEC itself does not provide any attestation of conformity Independent certification bodies provide conformity assessment services and, in some areas, access to IEC marks of conformity IEC is not responsible for any services carried out by independent certification bodies 6) All users should ensure that they have the latest edition of this publication 7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and members of its technical committees and IEC National Committees for any personal injury, property damage or other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC Publications 8) Attention is drawn to the Normative references cited in this publication Use of the referenced publications is indispensable for the correct application of this publication 9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of patent rights IEC shall not be held responsible for identifying any or all such patent rights International Standard IEC 61643-351 has been prepared by subcommittee 37B: Specific components for surge arresters and surge protective devices, of IEC technical committee 37: Surge arresters The text of this standard is based on the following documents: FDIS Report on voting 37B/155/FDIS 37B/156/RVD Full information on the voting for the approval of this International Standard can be found in the report on voting indicated in the above table This document has been drafted in accordance with the ISO/IEC Directives, Part BS EN 61643-351:2017 IEC 61643-351:2016 © IEC 2016 –5– A list of all parts in the IEC 61643 series, published under the general title Components for low-voltage surge protective devices, can be found on the IEC website Future standards in this series will carry the new general title as cited above Titles of existing standards in this series will be updated at the time of the next edition The committee has decided that the contents of this document will remain unchanged until the stability date indicated on the IEC website under "http://webstore.iec.ch" in the data related to the specific document At this date, the document will be • reconfirmed, • withdrawn, • replaced by a revised edition, or • amended –6– BS EN 61643-351:2017 IEC 61643-351:2016 © IEC 2016 INTRODUCTION This part of IEC 61643 covers surge isolation transformers whose rated impulse withstand voltage coordinates with the expected surge environment of the installation This type of surge protective component, SPC, isolates and attenuates transient voltages in conjunction with current diverting components (e.g GDT, MOV, etc.) or surge protective devices (SPDs) It can be used in SPDs BS EN 61643-351:2017 IEC 61643-351:2016 © IEC 2016 – 14 – C P-SA C P-Screen C S-Screen A ZS WS WP A ZT ES C P-Screen C S-Screen B B R C P-SB IEC Key W P: Primary winding C P-Screen A, C P-Screen B : Primary to screen capacitance, paths A and B W S: Secondary winding C S-Screen A , C S-Screen B : Secondary to screen capacitance, paths A and B ES: Electric screen C P-SA , C P-SB : ZS: Service source impedance R: Reference plane or point Primary to secondary unscreened capacitance, paths A and B Z T : Terminating or load impedance Figure – Common-mode surge conditions for SIT with an electric screen 5.2 Common-mode surges Figure shows SIT under common-mode surge conditions The insulation rated impulse voltage shall be equal to or greater than the peak common-mode surge voltage for insulation coordination (see 7.1) Any primary to secondary capacitance (shown as C P-SA + C P-SB ) that is not decoupled by the electric screen (ES) provides a capacitive current flow path from the primary to secondary circuit (see 6.2) The major parameters for common-mode surges are the rated impulse voltage and the internal-winding capacitance, plus a post-test insulation resistance check on the insulation integrity 5.3 Differential-mode surges Differential-mode surges are typically caused by system asymmetry converting what should be common-mode surges to differential ones SIT action occurs on differential-mode surges and the SIT does little to mitigate them In some cases SIT bandwidth will result in filtering of the output surge frequency spectrum Signal SITs may suffer core saturation, which truncates the secondary voltage Some standards specify testing for differential power faults, requiring the signal SIT to have a primary winding current rating BS EN 61643-351:2017 IEC 61643-351:2016 © IEC 2016 – 15 – Characteristics 6.1 Characteristic measurement Characteristics are measureable component parameters at the time of test and the values obtained are for the component tested Characteristics may be specified by the manufacturer as typical, maximum, minimum or combinations of these quantities The temperature and humidity environment for the characteristic measurements shall be IEC 60721-3-3, class 3K1: a) low temperature 20 °C ± °C; b) high temperature 25 °C ± °C; c) low relative humidity 20 %; d) high relative humidity 75 % 6.2 Input winding to output winding capacitance This test measures the effective internal-winding capacitance of SIT a) Test method Figure shows a test circuit to measure SIT internal-winding capacitance In Figure 7, only SIT capacitive component is shown Both the primary winding W P and secondary winding W S are short-circuited The internal-winding capacitance is measured between the two shorts WP WS C P-S F IEC Key W P : Primary winding C P-S : Primary to secondary capacitance W S : Secondary winding F: Capacitance meter Figure – Test circuit to measure SIT internal-winding capacitance Figure shows a test circuit to measure the internal-winding capacitance of SIT with an electric screen, ES In Figure 8, only SIT capacitive components are shown Both the primary winding W P and secondary winding W S are short-circuited The internal-winding capacitance is measured between the two shorts A guarded measurement of the internalwinding capacitance shall be made to remove the winding to electric screen capacitances Guarded measurements are done using either three-wire (Hi, Lo, Guard) or six-wire (Hi, Lo, Guard feed and Hi, Lo, Guard sense) techniques Figure shows the use of a Blumlein three-wire transformer ratio arm bridge The use of coaxial cables removes the connecting cable shunting capacitance from the measurement BS EN 61643-351:2017 IEC 61643-351:2016 © IEC 2016 – 16 – WP WS C P-S G G C S-Screen C P-Screen ES CL CH G G F IEC Key W P : Primary winding C P-Screen : Primary to Screen capacitance W S : Secondary winding C S-Screen : Secondary to Screen capacitance ES: Electric screen C P-S : Primary to Secondary residual capacitance C H : Capacitance measurement connection Hi G: Guard connection (coaxial cables screen) C L : Capacitance measurement connection Lo F: Guarded measurement capacitance bridge Figure – Test circuit to measure the internal-winding capacitance of SIT with an electric screen By connecting the guard G to the primary and the measurement leads to the two remaining connections, the secondary to electric screen capacitance C S-Screen may be measured Similarly, connecting the guard G to the secondary and the measurement leads to the two remaining connections, the primary to electric screen capacitance C P-Screen may be measured b) Values This document covers AC low frequency power, high frequency switching of any size and construction With this degree of variation, it is impractical to create a list of preferred values The internal-winding capacitance value can be used to predict the level of capacitive surge current passed on to the following circuitry c) Criteria The measured value of internal-winding capacitance shall be within the manufacturer’s specified limits When the manufacturer only gives a typical value, if the measured value is outside ±30 % the typical value, the manufacturer should be contacted to verify the measurement technique and product parameter distribution 6.3 Insulation resistance (IR) This test measures the resistance of the insulation at a defined DC voltage a) Test method The insulation resistance meter shall be set for the specified value of DC test voltage, see 6.3 b) The test voltage shall be applied for at least 60 s before the insulation resistance value is taken Figure shows the test circuit to measure the insulation resistance of SIT Both the primary winding W P and secondary winding W S are short-circuited The insulation resistance is measured between the two shorts BS EN 61643-351:2017 IEC 61643-351:2016 © IEC 2016 – 17 – WS WP Ω IEC Key W P : Primary winding Ω: IR meter with defined DC bias W S : Secondary winding Figure – Test circuit to measure the insulation resistance of SIT Figure 10 shows the test circuit to measure the insulation resistance of SIT with an electric screen Both the primary winding W P and secondary winding W S are short-circuited The insulation resistance is measured between the two shorts Unless otherwise specified, two measurements are taken: once with the selector switch SW connecting the electric screen ES to the primary winding W P , and once with the selector switch SW connecting the electric screen ES to the secondary winding W S WP ES WS SW Ω IEC Key W P : Primary winding Ω: IR meter with defined DC bias W S : Secondary winding SW: Two-position selector switch ES: Electric screen Figure 10 – Test circuit to measure the insulation resistance of SIT with an electric screen b) Value The preferred test value of DC voltage is 500 V and the resistance reading is made after the DC voltage has been applied for 60 s minimum c) Criteria The insulation resistance values shall be MΩ or more, measured at 500 V DC BS EN 61643-351:2017 IEC 61643-351:2016 © IEC 2016 – 18 – 6.4 Signal SIT voltage-time product This test measures SIT voltage-time product, a measure of the secondary winding differentialmode surge let-through a) Test method Figure 11 shows the test circuit for voltage-time measurement The pulse generator, G has adjustable voltage amplitude and pulse duration WP WS G VS O IEC Key W P : Primary winding G: Pulse generator, 50 Ω source impedance W S : Secondary winding O: Oscilloscope monitoring V S V S : Instantaneous secondary winding voltage Figure 11 – Test circuit to measure SIT voltage-time product VS VG Figure 12 shows the generator open-circuit output voltage and the resultant secondary winding voltage The generator pulse voltage amplitude V G and duration are adjusted to cause SIT core saturation Core saturation is shown by the secondary winding voltage pulse being truncated, having a shorter duration t S than the generator pulse To allow accurate measurement, the generator voltage amplitude shall be adjusted such that the core saturation time t S is not less than 10 μs tS 0,5V S IEC Key V G : Open-circuit pulse generator peak voltage t S : Secondary winding voltage time above 50 % V S V S : Instantaneous secondary winding peak voltage Figure 12 – Generator and SIT secondary voltage waveforms On the instantaneous secondary winding voltage V S , measure the peak amplitude V S and the 50 % V S duration time t S SIT voltage-time product is given by V S × t S expressed in μV·s b) Value SIT voltage-time product depends on SIT size, construction and the information and communications technology (ICT) system With this degree of variation, it is impractical to create a list of preferred values As an example, Ethernet SITs typically have a voltagetime product in the 50 μV·s region The voltage-time product value can be used to predict the peak secondary voltage level before truncation resulting from a defined surge waveform when there are no secondary voltages limiting components c) Criteria The measured value of voltage-time product shall be within the manufacturer’s specified limits When the manufacturer only gives a typical value, if the measured value is outside BS EN 61643-351:2017 IEC 61643-351:2016 © IEC 2016 – 19 – ±30 % the typical value, the manufacturer should be contacted to verify the measurement technique and product parameter distribution Ratings 7.1 Rated impulse withstand voltage This test verifies the insulation rated impulse voltage specified by SIT manufacturer for the component type a) Test method The insulation rated impulse voltage is traditionally tested using a 1,2/50 voltage impulse, see Annex A This document only specifies insulation impulse testing as it is a universal approach that can be used for component, device and equipment port testing Figure 13 shows the test circuit used for insulation voltage withstand testing of SIT A 1,2/50 impulse generator, whose voltage waveform is monitored by oscilloscope O, has its impulse voltage applied to the insulation separating windings W P and W S Both the primary winding W P and secondary winding W S are short circuited WS WP O G 1,2/50 IEC Key W P : Primary winding G: 1,2/50 surge generator W S : Secondary winding O: Oscilloscope or equivalent monitoring impulse voltage Figure 13 – SIT rated impulse voltage test circuit Figure 14 shows the test circuit used for insulation voltage withstand testing of SIT with an electric screen A 1,2/50 impulse generator, whose voltage waveform is monitored by oscilloscope O, has its impulse voltage applied to the insulation separating windings W P and W S Both the primary winding W P and secondary winding W S are short circuited Unless otherwise specified, two measurements are taken: once with the selector switch, SW connecting the electric screen ES to the primary winding W P , , and once with the selector switch SW connecting the electric screen ES to the secondary winding W S BS EN 61643-351:2017 IEC 61643-351:2016 © IEC 2016 – 20 – WP WS ES SW O G 1,2/50 IEC Key W P : Primary winding G: 1,2/50 surge generator W S : Secondary winding O: Oscilloscope or equivalent monitoring impulse voltage ES: Electric screen SW: Two-position selector switch Figure 14 – Rated impulse voltage test circuit for SIT with an electric screen d d Before testing the insulation, a test pass/fail template shall be determined First set the generator G voltage to the impulse withstand voltage listed in Table that corresponds to SIT rated impulse voltage Record the generator G voltage waveform Construct a template from the generator G open-circuit 1,2/50 waveform consisting of an upper limit, created by moving the waveform up by 10 % of the peak amplitude, and a lower limit, created by moving the waveform down by 10 % of the peak amplitude (see Figure 15) IEC Key d: Positive and negative vertical waveform displacement distance of the 1,2/50 open-circuit voltage waveform Distance d is equal to 10 % of the peak open-circuit voltage Figure 15 – Construction of pass/fail template from the 1,2/50 open-circuit waveform An example use of the template is shown in Figure 16, in which the template is shown as a shaded area To pass the insulation test, any waveform aberrations during the insulation test shall not be outside the template area (see Figure 16 a)) Any insulation breakdown causing aberrations such as waveform serration (Figure 16 b)) and truncation (Figure 16 c)) are outside the template area and are test failures BS EN 61643-351:2017 IEC 61643-351:2016 © IEC 2016 IEC a) Pass, test waveform within the template constructed from the 1,2/50 open circuit voltage waveform – 21 – IEC b) Test failure, serrated test waveform outside the template area IEC c) Test failure, truncated test waveform outside the template area Figure 16 – Pass/fail template and test waveforms Using the test circuits of Figure 13 or Figure 14, as appropriate, apply the impulse withstand test voltage corresponding to SIT insulation rated impulse voltage to the insulation from the impulse generator G, while recording the impulse waveform on oscilloscope O Check if the recorded voltage complies with Figure 16 a) For SIT with an electric screen, see Figure 14, repeat the test with the selector switch SW set in the alternative position and check if the recorded voltage complies with Figure 16 a) After the impulse withstand test, measure the insulation resistance as described in 6.3 b) Value Table lists the preferred values for SIT insulation rated impulse voltage together with the corresponding impulse withstand test voltage To ensure the insulation rated impulse voltage is at least its specified value the applied impulse withstand test voltage shall be higher in voltage The ratio of impulse withstand to rated impulse voltage used in Table is 1,17 for voltages less than kV and 1,23 for voltages of kV and above in accordance with IEC 60664-1 and IEC TR 60664-2-1:2011 The test setup measures the combined withstand of creepage, clearance and insulation barrier with the component mounted as specified – 22 – BS EN 61643-351:2017 IEC 61643-351:2016 © IEC 2016 Table – Impulse withstand test voltage for rated impulse voltage Rated impulse voltage Impulse withstand voltage a kV kV 0,8 0,94 1,5 1,75 2,1 b 2,4 2,5 2,92 4,92 7,39 9,85 10 12,3 12 14,8 15 18,5 25 30,8 30 36,9 40 49,2 60 73,9 80 98,5 120 148 NOTE The rated impulse voltage value of 10 kV is from ITU-T K.21 and ITU-T K.66 NOTE The rated impulse voltage value 30 kV is used in some countries a The 1,2/50 peak voltage amplitude tolerance shall be ±5 % in accordance with IEC TR 60664-2-1:2011 b Interpolated rated impulse voltage corresponding to the 1,2/50, 2,4 kV test value of ISO/IEC/IEEE 8802-3:2014 c) Criteria The waveform during testing shall comply with the requirements of Figure 16 a) and the after test insulation resistance shall comply with 6.3 7.2 Signal SIT rated winding direct current This test verifies that the specified winding conductor temperature rise, for the component type, is not exceeded at the rated SIT winding direct current This rating is only required when SIT is to be used in devices and equipment ports that are required to be tested under differential-mode AC power fault conditions a) Test method This test is applicable to copper conductor SIT windings and assumes SIT thermal resistance is constant Figure 17 shows the two measuring circuits used Circuit a) is to measure the pre-test values of winding resistance and ambient temperature Circuit b) is to measure the winding voltage at the rated direct current and the local ambient temperature of SIT after thermal equilibrium is reached As the winding temperature is not measured directly, thermal equilibrium is taken as when the measured winding voltage has a variation of less than 0,4 % between any two out of three consecutive measurements made at an interval of Generally most signal SITs will reach thermal equilibrium within 15 For these tests SIT shall be placed in a draught-free environment The pre-test values of winding resistance, R , and ambient temperature, T A1 , obtained from test circuit of Figure 17 a) shall be recorded The rated direct current, I DC , shall then BS EN 61643-351:2017 IEC 61643-351:2016 © IEC 2016 – 23 – be applied to SIT winding and the winding voltage measured at intervals of When it has been determined that thermal equilibrium has been reached, the winding voltage, V W , and local ambient temperature, T A2 , at that time shall be recorded The following calculations shall be done: Increase in resistance value, DR: DR = VW − R1 I DC (1) Increase in winding temperature, DT, using a 0,003 93 temperature coefficient for copper conductors: ∆T = ∆R 0,003 93 R1 (2) To compensate for any increase in local ambient temperature (T A2 − T A1 ), the effective temperature increase, DT DC , caused by I DC is calculated from: DTDC = DT − (TA2 − TA1 ) (3) °C °C + - + TC WP WP WS I Ω TC WS V IEC IEC a) b) Key W P : Primary winding Ω: Ohm meter to measure winding resistance W S : Secondary winding I: Current source set to the winding rated direct current, I DC TC: Thermocouple, placed 10 mm ±2 mm from SIT V: Voltmeter to measure winding voltage, V W °C: Meter measuring the local ambient temperature Figure 17 – Winding conductor temperature rise test circuit The insulation resistance (see 6.3) shall be measured after the test b) Value SIT primary rated winding direct current depends on SIT size, construction and the ICT system With this degree of variation, it is impractical to create a list of preferred values As an example, Ethernet SITs typically have a primary rated winding direct current for 40 °C temperature rise in the A region SIT rated winding direct current can be used to predict the maximum continuous rms power fault winding current that can be sustained before overcurrent protection is needed – 24 – BS EN 61643-351:2017 IEC 61643-351:2016 © IEC 2016 c) Criteria At the rated direct current the calculated winding temperature rise, ∆T DC , shall not exceed its specified value The testing shall not cause a hazard nor result in an insulation resistance lower than specified in 6.3 8.1 Identification General The following information shall be provided by the manufacturer 8.2 Datasheet Application information which shall be available in a product datasheet: a) rated impulse withstand voltage; b) signal performance 8.3 Marking Markings which are mandatory on the body, or permanently attached to the body: a) manufacturer's name or trade mark and model number; b) traceability information; c) microclimate (if applicable) BS EN 61643-351:2017 IEC 61643-351:2016 © IEC 2016 – 25 – Annex A (informative) 1,2/50 impulse Generators delivering 1,2/50 open-circuit voltage impulses at levels given in Table A.1 are commercially available Some generators, called combination wave generators, also deliver a defined 8/20 short-circuit current Generally 1,2/50–8/20 combination wave generators have a maximum open-circuit voltage of kV peak Voltage (%) Figure A.1 shows the time periods and amplitudes referenced in 3.1.18, 3.1.19 and 3.1.20 100 Peak Value 90 50 30 Time T T1 T2 O1 IEC Key T : Virtual front time = (1/0,6) × T O : Virtual origin T : Virtual time to half-value Figure A.1 – 1,2/50 time periods and voltage amplitudes Table A.1 shows the 1,2/50 waveform details Table A.1 – 1,2/50 voltage impulse generator parameters Designation 1,2/50 SOURCE: IEC 60060-1:2010 a Condition Open-circuit voltage Short-circuit current Period Time and tolerance T1 1,2 µs ± 30 % T2 50 µs ± 20 % Peak amplitude ±3 % a Current waveform not defined The 1,2/50 peak voltage amplitude tolerance for insulation testing can be increased to ±5 % in accordance with IEC TR 60664-2-1:2011 – 26 – BS EN 61643-351:2017 IEC 61643-351:2016 © IEC 2016 Bibliography [1] IEC 60060-1:2010, High-voltage test techniques – Part 1: General definitions and test requirements [2] IEC 60068-2-1:2007, Environmental testing – Part 2-1: Tests – Test A: Cold [3] IEC 60068-2-2:2007, Environmental testing – Part 2-2: Tests – Test B: Dry heat [4] IEC 60076-1, Power transformers – Part 1: General [5] IEC 60721-3-9:1993, Classification of environmental conditions – Part 3: Classification of groups of environmental parameters and their severities – Section 9: Microclimates inside products [6] IEC 60989, Separating transformers, autotransformers, variable transformers and reactors [7] IEC TR 61340-1:2012, Electrostatics – Part 1: Electrostatic phenomena – Principles and measurements [8] IEC 61340-4-8, Electrostatics – Part 4-8: Standard test methods for specific applications – Electrostatic discharge shielding – Bags [9] IEC 61558-1, Safety of power transformers, power supplies, reactors and similar products – Part 1: General requirements and tests [10] IEC 61558-2-4, Safety of transformers, reactors, power supply units and similar products for supply voltages up to 100 V – Part 2-4: Particular requirements and tests for isolating transformers and power supply units incorporating isolating transformers [11] IEC 61558-2-6, Safety of transformers, reactors, power supply units and similar products for supply voltages up to 100 V – Part 2-6: Particular requirements and tests for safety isolating transformers and power supply units incorporating safety isolating transformers [12] ISO/IEC 11801, Information technology – Generic cabling for customer premises [13] ITU-T K.21, Resistibility of telecommunication equipment installed in customer premises to overvoltages and overcurrents [14] ITU-T K.66, Protection of customer premises from overvoltages [15] ITU-T K.95, Surge parameters of isolating transformers used in telecommunication devices and equipment [16] IEEE PC62.69™/D4 Standard for the surge parameters of isolating transformers used in networking devices and equipment [17] ISO/IEC/IEEE 8802-3:2014, Standard for Ethernet [18] JEC0301, Standard of the Japanese electrical committee, Part 0301: Impulse voltage withstand tests for power transformers, reactors and instrument transformers _ This page deliberately left blank NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAW British Standards Institution (BSI) BSI is the national body responsible for preparing British Standards and other standards-related publications, information and services BSI is incorporated by Royal Charter British Standards and other standardization products are published by BSI Standards Limited About us Reproducing extracts We bring together business, industry, government, consumers, innovators and others to shape their combined experience and expertise into standards -based solutions For permission to reproduce content from BSI publications contact the BSI Copyright & Licensing team The knowledge embodied in our standards has been carefully assembled in a dependable format and refined through our open consultation process Organizations of all sizes and across all sectors choose standards to help them achieve their goals Information on standards We can provide you with the knowledge that your organization needs to succeed Find out more about British Standards by visiting our website at bsigroup.com/standards or contacting our Customer Services team or Knowledge Centre Buying standards You can buy and download PDF versions of BSI publications, including British and adopted European and international standards, through our website at bsigroup.com/shop, where hard copies can also be purchased If you need international and foreign standards from other Standards Development Organizations, hard copies can be ordered from our Customer Services team Copyright in BSI publications All the content in BSI publications, including British Standards, is the property of and copyrighted by BSI or some person or entity that owns copyright in the information used (such as the international standardization bodies) and has formally licensed such information to BSI for commercial publication and use Save for the provisions below, you may not transfer, share or disseminate any portion of the standard to any other person You may not adapt, distribute, commercially exploit, or publicly display the standard or any portion thereof in any manner whatsoever without BSI’s prior written consent Storing and using standards Standards purchased in soft copy format: • A British Standard purchased in soft copy format is licensed to a sole named user for personal or internal company use only • The standard may be stored on more than device provided that it is accessible by the sole named user only and that only copy is accessed at any one time • A single paper copy may be printed for personal or internal company use only Standards purchased in hard copy format: • A British Standard purchased in hard copy format is for personal or internal company use only • It may not be further reproduced – in any format – to create an additional copy This includes scanning of the document If you need more than copy of the document, or if you wish to share the document on an internal network, you can save money by choosing a subscription product (see ‘Subscriptions’) Subscriptions Our range of subscription services are designed to make using standards easier for you For further information on our subscription products go to bsigroup.com/subscriptions With British Standards Online (BSOL) you’ll have instant access to over 55,000 British and adopted European and international standards from your desktop It’s available 24/7 and is refreshed daily so you’ll always be up to date You can keep in touch with standards developments and receive substantial discounts on the purchase price of standards, both in single copy and subscription format, by becoming a BSI Subscribing Member PLUS is an updating service exclusive to BSI Subscribing Members You will automatically receive the latest hard copy of your standards when they’re revised or replaced To find out more about becoming a BSI Subscribing Member and the benefits of membership, please visit bsigroup.com/shop With a Multi-User Network Licence (MUNL) you are able to host standards publications on your intranet Licences can cover as few or as many users as you wish With updates supplied as soon as they’re available, you can be sure your documentation is current For further information, email subscriptions@bsigroup.com Revisions Our British Standards and other publications are updated by amendment or revision We continually improve the quality of our products and services to benefit your business If you find an inaccuracy or ambiguity within a British Standard or other BSI publication please inform the Knowledge Centre Useful Contacts Customer Services Tel: +44 345 086 9001 Email (orders): orders@bsigroup.com Email (enquiries): cservices@bsigroup.com Subscriptions Tel: +44 345 086 9001 Email: subscriptions@bsigroup.com Knowledge Centre Tel: +44 20 8996 7004 Email: knowledgecentre@bsigroup.com Copyright & Licensing Tel: +44 20 8996 7070 Email: copyright@bsigroup.com BSI Group Headquarters 389 Chiswick High Road London W4 4AL UK

Ngày đăng: 15/04/2023, 10:28

TÀI LIỆU CÙNG NGƯỜI DÙNG

TÀI LIỆU LIÊN QUAN